Polyacetal rod fixation of fractures in osteoporotic bone. A preliminary report.
نویسنده
چکیده
Intramedullary rods manufactured from polyacetal were used to fix diaphyseal fractures in osteoporotic bone. They are pliable and can be introduced without further damage to such bone. Their low elastic modulus induces abundant callus. They can be locked with cortical bone screws without the need of jigs or radiographic control. Nine femoral and five tibial fractures were fixed in 10 patients, all with osteoporosis; 13 united primarily; one required bone grafting. No implant broke; however, no ambulant patient weighed more than 75 kg. The rods offer a promising treatment for diaphyseal fractures in osteoporotic bone.
منابع مشابه
The Photodynamic Bone Stabilization System: a minimally invasive, percutaneous intramedullary polymeric osteosynthesis for simple and complex long bone fractures
The treatment of osteoporotic long bone fractures is difficult due to diminished bone density and compromised biomechanical integrity. The majority of osteoporotic long bone fractures occur in the metaphyseal region, which poses additional problems for surgical repair due to increased intramedullary volume. Treatment with internal fixation using intramedullary nails or plating is associated wit...
متن کاملManagement of Type II Odontoid Fracture for Osteoporotic Bone Structure: Preliminary Report.
AIM Anterior transodontoid screw fixation technique is generally chosen for the management of type II odontoid fractures. The nonunion of type II odontoid fractures is still a major problem especially in elderly and osteoporotic patients. Eleven osteoporotic type II odontoid fracured patients were presented in this article. MATERIAL AND METHODS We have divided 11 patients in two groups as cla...
متن کاملAn Unusual Case of a Large Hematorrachis Associated with Multi-Level Osteoporotic Vertebral Compression Fractures; a Case Report
Spinal epidural haemorrhage may present as back pain associated with radicular symptoms and can be a catastrophic clinical scenario with progression to paraplegia or even sudden death. Being a rare entity, it needs a high index ofclinical suspicion to diagnose it. Fractures have been documented as a cause of hematorrachis but such hematomas only extend to one or two vertebral segments. Large ep...
متن کاملA locking contoured plate for distal fibular fractures: mechanical evaluation in an osteoporotic bone model using screws of different length.
Osteoporotic bone with poor mechanical capacity provides limited stability after fixation of ankle fractures. Stabilization with an implant providing increased fixation strength in osteoporotic bone could reduce failure rates of fixation and allow a more functional treatment. The purpose of this study was to evaluate a locking contoured plate for fixation of distal fibular fractures in comparis...
متن کاملRevision Fixation of Distal Humerus Fracture Nonunions in Older Age Patients with Poor Bone Quality or Bone Loss – Is This Viable as a Long-term Treatment Option?
Background: The purpose of this retrospective study was to analyze the long-term results of revision ORIF, jointcontracture release, and autogenous bone-grafting in the treatment of distal humerus frac-ture nonunions in older agedpatients with poor bone quality or bone loss who would have been candidates for total elbow arthroplasty.Methods: Seven patients (average age at inde...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 73 3 شماره
صفحات -
تاریخ انتشار 1991