MIRD Pamphlet No. 14 revised: A dynamic urinary bladder model for radiation dose calculations. Task Group of the MIRD Committee, Society of Nuclear Medicine.

نویسندگان

  • S R Thomas
  • M G Stabin
  • C T Chen
  • R C Samaratunga
چکیده

UNLABELLED The constant-volume urinary bladder model in the standard MIRD Pamphlet No. 5 (Revised) phantom has recognized limitations. Various investigators have developed detailed models incorporating more physiologically realistic features, such as expanding bladder contents and residual volume, and variable urinary input rate, initial volume and first void time. We have reviewed these published models and have developed a new model for calculation of radiation absorbed dose to the urinary bladder wall incorporating these aspects. METHODS The model consists of a spherical source with variable volume to simulate the bladder contents and a wall represented by a spherical shell of constant volume. The wall thickness varies as the source expands or contracts. The model provides for variable urine entry rate (three different hydration states), initial bladder contents volume, residual volume and first void time. The voiding schedule includes an extended nighttime gap during which the urine entry rate is reduced to one-half the daytime rate. RESULTS Radiation-absorbed dose estimates have been calculated for the bladder wall surface (including photon and electron components) and at several depths in the wall (electron component) for 2-18F-fluoro-2-deoxy-D-glucose, 99mTc-diethylenetriaminepentaacetic acid (DTPA), 99mTc-HEDP, 99mTc-pertechnetate, 99mTc-red blood cells (RBCs), 99mTc-glucoheptonate, 99mTc-mercaptoacetyltriglicine chelator (MAG3), 99mTc-methylene diphosphonate (MDP), 99mTc-hexamethylpropylene amine oxime (HMPAO), 99mTc-human serum albumin (HSA), 99mTc-MIBI (rest and stress), 123I-/124I-/131I-OIH, 123I/131I-NaI, 125I-iothalamate, 111In-DTPA and 89Sr-SrCl. CONCLUSION The new model tends to give a higher radiation absorbed dose to the bladder wall surface than the previous models. Large initial bladder volumes and higher rates of urine flow into the bladder result in lower bladder wall dose. The optimal first voiding time is from 40 min to 3 hr postadministration, depending on radiopharmaceutical. The data as presented in tabular and graphic form for each compound provide guidance for establishing radiation absorbed dose reduction protocols.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MIRD pamphlet No. 21: a generalized schema for radiopharmaceutical dosimetry--standardization of nomenclature.

The internal dosimetry schema of the Medical Internal Radiation Dose (MIRD) Committee of the Society of Nuclear Medicine has provided a broad framework for assessment of the absorbed dose to whole organs, tissue subregions, voxelized tissue structures, and individual cellular compartments for use in both diagnostic and therapeutic nuclear medicine. The schema was originally published in 1968, r...

متن کامل

Toward patient-friendly cell-level dosimetry.

Dosimetry for targeted radionuclide therapy is a relatively young field. Although initial work can be traced back to the late 1940s (1), the MIRD Committee formalism that forms the foundation for most current approaches was published in the mid 1970s (2), and the drive for improved dosimetry to meet the requirements of targeted radionuclide therapy did not begin until the 1980s. During this per...

متن کامل

MIRD Pamphlet No. 17: The Dosimetry of Nonuniform Activity Distributions—Radionuclide S Values at the Voxel Level

In collaboration with the MIRD Committee, Society of Nuclear Medicine: E.E. Watson (Chair), J.S. Robertson (Task Group Leader), W.E. Bolch, A.B. Brill, N.D. Charkes, D.R. Fisher, M.T. Hays, R.W. Howell, J.A. Siegel, S.R. Thomas and B.W. Wessels Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, Florida; Gaithersburg, Maryland; Department of Radiology, George...

متن کامل

MIRD pamphlet No. 24: Guidelines for quantitative 131I SPECT in dosimetry applications.

The reliability of radiation dose estimates in internal radionuclide therapy is directly related to the accuracy of activity estimates obtained at each imaging time point. The recently published MIRD pamphlet no. 23 provided a general overview of quantitative SPECT imaging for dosimetry. The present document is the first in a series of isotope-specific guidelines that will follow MIRD 23 and fo...

متن کامل

Patient dose calculation software in nuclear medicine [Persian]

  Introduction: Radioactive materials deliver internal radiation dose to patients in nuclear medicine. Manual internal radiation dose assessment is a complicated method. Introduction of a simple dose calculation software is the main goal of the present study. Methods: Using the best current data in internal dose calculation (S-Factors) recommended by ICRP and by cons...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 40 4  شماره 

صفحات  -

تاریخ انتشار 1999