Revision arthroscopic rotator cuff repair: repair integrity and clinical outcome: surgical technique.
نویسندگان
چکیده
BACKGROUND Literature regarding the outcomes of revision rotator cuff repair is limited. The purposes of the present study were to report the tendon repair integrity and clinical outcomes for a cohort of patients following revision arthroscopic rotator cuff repair and to examine factors related to tendon healing and the influence of healing on clinical outcomes. METHODS Twenty-one of twenty-nine consecutive revision arthroscopic rotator cuff repairs with a minimum of two years of postoperative follow-up were retrospectively reviewed. Outcomes were evaluated on the basis of a visual analog pain scale, the range of motion of the shoulder, the Simple Shoulder Test, the American Shoulder and Elbow Surgeons score, and the Constant score. Ultrasonography was used to examine repair integrity at a minimum of one year following surgery. Ten shoulders underwent arthroscopic repair of a recurrent single-tendon posterior rotator cuff tear, whereas eleven shoulders had repair of both the supraspinatus and infraspinatus. RESULTS The mean age of the twenty-one subjects was 55.6 years; thirteen subjects were male and eight were female. Complete preoperative and postoperative clinical data were available for nineteen subjects after an average duration of follow-up of thirty-three months. Significant improvements were seen in terms of postoperative pain (p < 0.05), the Simple Shoulder Test score (p < 0.05), the American Shoulder and Elbow Surgeons function (p < 0.05) and total scores (p < 0.05), active forward elevation (p < 0.05), and active external rotation (p < 0.05). Postoperative ultrasound data were available for all twenty-one shoulders after a mean duration of follow-up of twenty-five months. Ten (48%) of the twenty-one shoulders had an intact repair. Seven (70%) of the ten single-tendon repairs were intact, compared with three (27%) of the eleven supraspinatus/infraspinatus repairs (p = 0.05). Patient age (p < 0.05) and the number of torn tendons (p = 0.05) had significant effects on postoperative tendon repair integrity. Shoulders with an intact repair had better postoperative Constant scores (p < 0.05) and scapular plane elevation strength (p < 0.05) in comparison with those with a recurrent tear. CONCLUSIONS Revision arthroscopic rotator cuff repair results in reliable pain relief and improvement in shoulder function in selected cases. Approximately half of the revision repairs can be expected to be intact at a minimum of one year following surgery. Patient age and the number of torn tendons are related to postoperative tendon integrity. The postoperative integrity of the rotator cuff can have a significant influence on shoulder abduction strength and the Constant score.
منابع مشابه
Preliminary Results of a Consecutive Series of Large & Massive Rotator Cuff Tears Treated with Arthroscopic Rotator Cuff Repairs Augmented with Extracellular Matrix
Background: Recurrence rate of rotator cuff tears is still high despite the improvements of surgical techniques, materials used and a better knowledge of the healing process of the rotator cuff tendons. Large to massive rotator cuff tears are particularly associated with a high failure rate, especially in elderly. Augmentation of rotator cuff repairs with extracellular matrix or synthetic patc...
متن کاملSurface-holding repair: an original arthroscopic rotator cuff repair technique.
BACKGROUND Arthroscopic rotator cuff repair provides satisfactory results; however, there is still a high rate of re-tear. The objective of this study was to present a surface-holding technique that we recently developed for arthroscopic rotator cuff repair in detail and to evaluate the clinical outcome as well as cuff repair integrity with this new method. MATERIALS AND METHODS A consecutive...
متن کاملRehabilitation after Rotator Cuff Repair
BACKGROUND Rotator cuff tears are a very common condition that is often incapacitating. Whether non-surgical or surgical, successful management of rotator cuff disease is dependent on appropriate rehabilitation. If conservative management is insufficient, surgical repair is often indicated. Postsurgical outcomes for patients having had rotator cuff repair can be quite good. A successful outcome...
متن کاملOutcome and Structural Integrity of Rotator Cuff after Arthroscopic Treatment of Large and Massive Tears with Double Row Technique: A 2-Year Followup
Purpose. The purpose of this study was to evaluate the functional outcome and the tendon healing after arthroscopic double row rotator cuff repair of large and massive rotator cuff tears. Methods. 82 patients with a full-thickness large and massive rotator cuff tear underwent arthroscopic repair with double row technique. Results were evaluated by use of the UCLA, ASES, and Constant questionnai...
متن کاملThe outcome and structural integrity of arthroscopic rotator cuff repair with use of the double-row suture anchor technique.
BACKGROUND The reported rate of failure after arthroscopic rotator cuff repair has varied widely. The influence of the repair technique on the failure rates and functional outcomes after open or arthroscopic rotator cuff repair remains controversial. The purpose of the present study was to evaluate the functional and anatomic results of arthroscopic rotator cuff repairs performed with the doubl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. American volume
دوره 92 3 شماره
صفحات -
تاریخ انتشار 2010