Frequency and characteristics of coagulopathy in trauma patients treated with a low- or high-plasma-content massive transfusion protocol.

نویسندگان

  • Linda A Chambers
  • Stuart J Chow
  • Lynn E T Shaffer
چکیده

A massive transfusion protocol (MTP) in which most non-RBC transfusions were laboratory result-driven was updated to a 1:1:1 RBC/plasma/platelet formula-driven protocol. Platelet count, fibrinogen level, and prothrombin time (PT) were monitored. In the patients who survived the first 12 hours, the results of coagulation tests were analyzed. Irrespective of the MTP or transfused RBC/plasma ratio, a majority of patients became coagulopathic, usually within the first 2 hours, and a fibrinogen deficiency (fibrinogen level, <100 mg/dL [2.9 μmol/L]) was almost always the initial abnormality. The laboratory value trends under each MTP were indistinguishable: PTs were prolonged and platelet counts and fibrinogen levels fell during the first 100 minutes and then corrected back toward baseline. More than 80% of patients in each group were noncoagulopathic at 12 hours. A 1:1:1 formula-driven MTP did not affect the frequency, nature, or duration of coagulopathy according to laboratory test results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Massive transfusion practices around the globe and a suggestion for a common massive transfusion protocol.

BACKGROUND Massive transfusion, the administration of 10 to more than 100 units of red blood cells (RBC) in less than 24 hours, can be a life saving therapy in the treatment of severe injury. The rapid administration of large numbers of RBC, along with sufficient plasma and platelets to treat or prevent coagulopathy, is frequently a disorderly process. Patient care and collaborative research mi...

متن کامل

Current management of massive hemorrhage in trauma

Hemorrhage remains a major cause of potentially preventable deaths. Trauma and massive transfusion are associated with coagulopathy secondary to tissue injury, hypoperfusion, dilution, and consumption of clotting factors and platelets. Concepts of damage control surgery have evolved prioritizing early control of the cause of bleeding by non-definitive means, while hemostatic control resuscitati...

متن کامل

The ratio of blood products transfused affects mortality in patients receiving massive transfusions at a combat support hospital.

BACKGROUND Patients with severe traumatic injuries often present with coagulopathy and require massive transfusion. The risk of death from hemorrhagic shock increases in this population. To treat the coagulopathy of trauma, some have suggested early, aggressive correction using a 1:1 ratio of plasma to red blood cell (RBC) units. METHODS We performed a retrospective chart review of 246 patien...

متن کامل

The effects of prehospital plasma on patients with injury: a prehospital plasma resuscitation.

BACKGROUND The prehospital resuscitation of the exsanguinating patient with trauma is time and resource dependent. Rural trauma care magnifies these factors because transportation time to definitive care is increased. To address the early resuscitation needs and trauma-induced coagulopathy in the exsanguinating patient with trauma an aeromedical prehospital thawed plasma-first transfusion proto...

متن کامل

Monitoring the coagulation status of trauma patients with viscoelastic devices

Coagulopathy is a physiological response to massive bleeding that frequently occurs after severe trauma and is an independent predictive factor for mortality. Therefore, it is very important to grasp the coagulation status of patients with severe trauma quickly and accurately in order to establish the therapeutic strategy. Judging from the description in the European guidelines, the importance ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 136 3  شماره 

صفحات  -

تاریخ انتشار 2011