Measurements of thoron (""Rn) have been performed in some 90 buildings during 1992 and 1993, as parts of two different investigations. The measurements were performed in order to form a basis for assessing the risk for high thoron levels indoors in Sweden. In the first study thoron progeny measurements were undertaken in 53 dwellings and 7 workplaces at 13 different locations in south and central Sweden. Most buildings were situated in areas with elevated natural thorium concentrations. In each dwelling two measurements were made; in the livingroom or a bedroom and in the basement. The radon P R n ) progeny concentration was measured at the same time and the thorium and uranium activty concentrations in the rock and soil surrounding the buildings were measured with a portable gamma spectrometer. Typical thoron progeny values (Equilibrium Equivalent concentration of Thoron, EET) in the living areas were in the range 0.1 to 1.0 Bq.mm3 (8 to 76 I L T . ~ ' ~ , 0.4 to 3.6 mWL, Potential Alpha Energy Concentration, PAEC and Working Level for thoron progeny) with a mean of 0.9 Bq.m-3 (68 x~J.m-~, 3.3 mWL). The measurements in the basements had a mean of 1.5 Bq.m'3 (114 x~J.m-~. 5.5 mWL). A few measurements of thoron gas were performed in basements and showed typical values between 10 and 80 Bq.mh3. with a maximum of 430 Bq.m4. As part of a study of long-term variations of =RII in dwellings located in different parts of Sweden, 24 hour continuous measurements of thoron gas were performed in 28 of these dwellings. In this study the buildings were chosen regardless of natural thorium concentrations. The mean of these measurements was 13 Bq.nr3. One high value of 150 Bq.m-3 was found. The estimated population mean for thoron progeny in Swedish homes is 0.5 Bq.m"3 (38 nJ.m4, 1.8 mWL). This would five an approximate annual effective dose to the average Swede of 0.1 mSv. INTRODUCTION Thoron (""Rn) has a short half-life, 55.6 seconds, compared to radon YRn) with a half-life of 3.8 days. This means that the distance that the thoron gas atoms can migrate in the ground and inside building materials and buildings before it decays is much shorter than for radon gas and also that it is comparatively easily stopped by wall paper and other surface sealants. Therefore the risk for high thoron levels indoors can be expected to be low, at least much lower than the risk for high levels of radon. However, in buildings with an ineffective barrier between soil and indoor air the entry of thoron could be significant, especially if the gravel or sand filler or the soil itself immediately under the building has a high concentration of T̂h. Soil as a significant source of indoor thoron has been demonstrated by Li and coworkers (Li et al., 1992). The release of thoron from building materials has also to be considered, especially where unsealed surfaces are present, such as bare walls, floors or ceilings. Under certain circumstances outdoor air can probably also be a source of high thoron levels indoors. The concentration of thoron outdoors has been measured as high as 200 Bq.ma3 at 1 m above ground (PorstendOrfer, 1994). and is strongly dependent on height. A few cm above ground the thoron concentration can be an order of magnitude higher. In Sweden, as part of this study the thoron gas concentration outdoors at a site near one of the office buildings of our institute was measured for about two months beginning September 1991. The thoron concentration was measured at 10 cm above ground and was found to vary between 20 Bq.m"3 and 330 Bq.m"3 with an 1995 International Radon Symposium 111 4.1 approximate mean of 90 Bq.me3. If the outdoor thoron concentration is high and the air inlet ducts are placed near the ground, outdoor air could be a source of indoor thoron. In 1990-1991 a pilot study on thoron progeny in dwellings and workplaces was performed in Sweden (MjOnes et al., 1992). In order to further assess the risk for high thoron levels indoors, the Swedish Radiation Protection Institute (SSI), has performed measurements of thoron and thoron progeny in some 90 buildings. Most measurements were made during 1992 and 1993, as parts of two different investigations. In the first study, here called study No. 1, thoron progeny measurements were undertaken in some 45 single-family houses and in a small number of apartments in multi-family buildings and workplaces situated in south and central Sweden. Most buildings in study No. 1 were situated in areas with elevated natural thorium concentrations. Sweden has several areas with natural thorium concentrations of 200-500 Bq.kgal. As part of an ongoing study of long-term variations of radon in 158 single-family houses located in different parts of Sweden, 24 hour continuous measurements of thoron gas were performed in 28 of these houses. In this study, called study No. 2, the buildings were chosen regardless of natural thorium concentrations (Hubbard et al., 1995) ENVIRONMENTAL LEVELS OF THORON Data on indoor thoron are limited. Surveys from different countries show mean thoron progeny values (Equilibrium Equivalent concentration of Thoron, EET) from 0.3 Bq.mm3 to 3.5 Bq.m'3 (23 U I . ~ ' ~ to 265 D J . ~ ~ , 1.1 mWL to 12.7 mWL, Potential Alpha Energy Concentration, PAEC and Working Level for thoron progeny), with most means below 1.0 Bq.nr3 (76 I I J . ~ ~ , 3.6 mWL) (MjOnes et al,, 1992, Steinbausler et al. 1994). The most extensive surveys have been performed in the UK, Germany and France. In the UK, measurements have been made in 390 dwellings. The mean of these measurements was 0.6 Bq.m-3 (46 nJ.mm3, 2.2 mWL). According to the authors, results from measurements in 150 dwellings in the Pennines, with a mean of 0.3 Bq.m-3 (23 x~.J.m"~, 1.1 mWL), are more likely to be typical of the concentrations in UK dwellings (Wrixon et al., 1988). This has been confirmed by measurements in 50 dwellings in five major cities in the UK (Cliff et al., 1992). In Germany Keller and coworkers (Keller et al., 1982) have published results from measurements in 148 homes with a median of 0.3 Bq.me3 (23 I I J . ~ ' ~ , 1.1 mWL). From two departments in a granitic area in Brittany in western France medians of 0.7 and 0.8 Bq.m-3 (53 and 61 nJ.m-3, 2.5 and 2.9 mWL) have been reported (Rannou et al., 1988). Schery has measured ^Pb at 68 indoor locations in 18 states in the United States and found a mean of 0.28 Bq.m-3 (21 nJ.nr3, 1.0 mWL) (Schery, 1985). In Elliot Lake in Canada 95 dwellings have been investigated with a mean of 1.5 Bq.m-3 ( 1 14 nJ.rn-3, 5.5 mWL) (Gunning and Scott. 1982). Thoron progeny investigations have also been reported from, for example, Norway and Hong Kong (Stranden, 1980, Tso and Li, 1987). In recent years several investigations concerning thoron have been performed by Japanese research groups. They have found relatively high levels of thoron progeny and thoron gas in traditional Japanese buildings with one or more walls covered with a widely used soil-based plaster. Guo and coworkers (Guo et al., 1992 ) have found a mean thoron progeny concentration of 3.5 Bq.m'3 (265 nJ.mm3, 12.7 mWL) in 4 houses with plaster walls in the Nagoya area. A mean thoron gas concentration of 394 Bq.m'3 was found from measurements in 9 such houses (Guo et aL, 1 993). Doi and coworkers have measured activity concentrations of thoron gas in 21 houses in the Hiroshima prefecture with a mean of 85 Bq.mm3 and a maximum of 550 Bq.rn'3. The measurements were made 20 cm from a wall (Doi et al., 1994b). Several investigations show that the thoron concentration decreases exponentially with the distance from a soil-plastered wall (Doi et al., 1994a. Guo et al., 1993). Measurements of the concentration of % in the soil have shown values of about 90 Bq.kg-' in the Hiroshima area (Doi et al., 1994b) and about 35 Bq.kg" in the Nagoya area (Guo et al., 1992). The Swedish preliminary study included thoron progeny measurements in nine dwellings, eight basements and four workplaces in 12 different buildings. In this study the mean thoron progeny concentration in the measured dwellings was 0.3 Bq.m-3 (EET) (23 I I J . ~ . ~ , 1.1 mWL) and in the basements 1.5 Bq.m-3 (114 nJ.rn-'. 5.5 mWL). 1995 International Radon Symposium I11 4.2 measured with a gamma meter and a portable g k spectrometer. In study No. 2, continuous measurements of thoron gas were performed. In this study the buildings were chosen regardless of natural thorium concentrations. 24 hour measurements were made in one room, mostly the living-room or a bedroom, in the ground floor or in the basement. The thoron gas meter was placed on the floor close to one of the walls. Simultaneous radon gas measurements were performed with the same equipment as in study No. 1. Thoron gas measurements The thoron gas measurements were performed with the Falk-More-Nyblom multiple time analysis method (Falk et al., 1992). The technique is based on selective alpha-counting of the short-lived nuclide 216Po. half-life 0.145 s. The alpha particle from the decay of a ""Rn atom will be followed, within a fraction of a second, by an alpha particle from the decay of '̂Po. By measuring the time interval between succesive alpha counts and a following multiple time analysis, the '̂'Po activity and thereby the ""Rn activity can be calculated. The detector is a commercial radon monitor using a 160 ml Lucas type scintillator cell working in flow-through mode. Air is sucked through a filter to remove any airborne particles and decay products from ""Rn and ^Rn before entering the sensitive volume. The flow rate was 1.5 liter per minute. Thoron uroeenv measurements The progeny measurements have been performed using alpha spectroscopy with two postsampling counting periods. The general outline of this method has been presented by several authors, for example Martz and coworkers (Martz et al., 1969). At the sampling place air is pulled through a 180 mesh wire screen (to measure the unattached fraction of radon and thoron progeny) and a 0.8 pm millipore filter at a rate of approximately 15 l.min-'. The air volume is measured with a gas meter. The radiation on the filter and the wire screen is counted with a surface barrier silicon alpha detector and a PC-based spectroscopy system. The sampling time was 60 minutes and the filter and the wire screen were first counted for 22 minutes followed by a 35 minute interval and then a second count was taken for 61 minutes. Using three energy channels and the two counting periods the concentrations of ̂ ^Po (RaA), ^Pb (RaB), '"Bi (RaC), ^Pb (ThB) and ^12Bi/̂ Po (ThC/ThC') and consequently the equilibrium equivalent concentrations of radon and thoron (EER and EET) can be calculated. The equipment has been calibrated in one of the radon chambers at the Swedish Radiation Protection Institute (Falk et al., 1994). Other measurements The radon gas measurements were made with a commercial continuous radon gas monitor (Baltzer et al., 1992). A portable NaI-based 256 channel gamma spectrometer was used for the measurements of thorium and uranium concentrations in the rock and soil surrounding the buildings and a commercial NaI gamma meter was used for the gamma radiation measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Thoron and Its Progeny in Traditional and Modern Earthen Buildings in Germany: Methodology and Results

In the past, the radon isotope Rn (thoron) was often paid little attention in the context of radiation protection at home. Measurements in buildings on the Central-Chinese Loess Plateau have shown, however, that in dwellings built from unfired earthen material, thoron and its progenies can significantly contribute to the inhalation dose of the dwellers. In Germany, such buildings mainly compris...

متن کامل

The Influence of Internal Wall and Floor Covering Materials and Ventilation Type on Indoor Radon and Thoron Levels in Hospitals of Kermanshah, Iran

BACKGROUND Building materials and the ventilation rate of a building are two main factors influencing indoor radon and thoron levels (two radioactive gases which have the most important role in human natural radiation exposure within dwellings). OBJECTIVES This analytical descriptive study was intended to determine the relationship between indoor radon and thoron concentrations and the buildi...

متن کامل

Levels of natural radioactivity in environment in residential area of Moradabad District, Western Uttar Pradesh

Indoor radon and thoron have been measured in the houses ofMoradabad District, Uttar Pradesh India, by means of solid state nuclear trackdetectors. Radon, an invisible radioactive gas, occurs naturally in indooratmospheres and along with thoron is the most important contribution of humanexposure to natural sources. Radon exists in soil gas building materials and indooratmosphere to name but a f...

متن کامل

Levels of natural radioactivity in environment in residential area of Moradabad District, Western Uttar Pradesh

Indoor radon and thoron have been measured in the houses ofMoradabad District, Uttar Pradesh India, by means of solid state nuclear trackdetectors. Radon, an invisible radioactive gas, occurs naturally in indooratmospheres and along with thoron is the most important contribution of humanexposure to natural sources. Radon exists in soil gas building materials and indooratmosphere to name but a f...

متن کامل

Intercomparison between Radon Passive and Active Measurements and Problems Related to Thoron Measurements

Researchers around the world had already established that radon and thoron are a hazard to the human health. Different techniques and methods are applied in order to measure them as accurately as possible. In Romania, most measurements earlier conducted were focused on using grab-sampling measurements to establish the two gasses decay progeny activity concentration; however, recently, there has...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007