A short-term clinical study of marginal bone level change around microthreaded and platform-switched implants
نویسندگان
چکیده
PURPOSE The marginal bone levels around implants following restoration are used as a reference for evaluating implant success and survival. Two design concepts that can reduce crestal bone resorption are the microthread and platform-switching concepts. The aims of this study were to analyze the placement of microthreaded and platform-switched implants and their short-term survival rate, as well as the level of bone around the implants. METHODS The subjects of this study were 27 patients (79 implants) undergoing treatment with microthreaded and platform-switched implants between October 2008 and July 2009 in the Dental Hospital of Yonsei University Department of Periodontology. The patients received follow-up care more than 6 months after the final setting of the prosthesis, at which time periapical radiographs were taken. The marginal bone level was measured from the reference point to the lowest observed point of contact between the marginal bone and the fixture. Comparisons were made between radiographs taken at the time of fixture installation and those taken at the follow-up visit. RESULTS During the study period (average of 11.8 months after fixture installation and 7.4 months after the prosthesis delivery), the short-term survival rate of microthreaded and platform-switched implants was 100% and the marginal bone loss around implants was 0.16±0.08 mm, the latter of which is lower than the previously reported values. CONCLUSIONS This short-term clinical study has demonstrated the successful survival rates of a microthread and platform-switched implant system, and that this system is associated with reduced marginal bone loss.
منابع مشابه
Evaluation of Marginal Bone Level around Platform - Switched Implants
Purpose: The long-term success of an implant depends on the stability of bone support for the implant. Most crestal bone loss occurs in the first year of implant placement. Platform-switching is an approach which can be clinically applied to preserve the crestal bone. The concept of ‘platform switching’ refers to the use of a smaller-diameter abutment on a larger-diameter implant collar. The pu...
متن کاملMarginal bone loss around platform-switched and non-platform switched implants after two years of placement: a clinical trial
Background. The present study was conducted to investigate the marginal bone loss around two different types of implant‒abutment junctions, called platform-switched (Implantium system) and non-platform switched (XiVE system) after two years of loading. Methods. Sixty-four implants in 49 patients were included in the study. The implants were placed in the posterior mandibular region according to...
متن کاملPlatform switching for marginal bone preservation around dental implants: a systematic review and meta-analysis.
BACKGROUND Platform switching for maintaining peri-implant bone levels has gained popularity among implant manufacturers over the last few years. However, the assumption that the inward shifting of the implant-abutment junction may preserve crestal bone was primarily based on serendipitous finding rather than scientific evidence. The objectives of the present study were to systematically review...
متن کاملMarginal bone loss evaluation around immediate non-occlusal microthreaded implants placed in fresh extraction sockets in the maxilla: a 3-year study.
OBJECTIVE To evaluate marginal bone loss over 3 years around immediate microthreaded implants placed in the maxillary anterior/esthetic zone and immediately restored with single crowns. MATERIAL AND METHODS Seventy-one implants (with microthreads up to the platform--rough surface body and neck, internal connection and platform switching) were placed in fresh extraction sockets in the maxillar...
متن کاملPlatform switching for marginal bone preservation around dental implants: a systematic review and meta-analysis
BACKGROUND: Platform switching for maintaining peri-implant bone levels has gained popularity among implant manufacturers over the last few years. However, the assumption that the inward shifting of the implant-abutment junction may preserve crestal bone was primarily based on serendipitous finding rather than scientific evidence. The objectives of the present study were to systematically revie...
متن کامل