Realization of a (400 A/DC-10 MHz) clamping HOKA current probe
نویسنده
چکیده
This work presents a first approach in high fidelity current measurement using GMR (giant magneto resistance) sensors combined along with an air coil to obtain a wide bandwidth current probe. The proposed probe is a prototype of a clamping version capable to capture currents of +/400 amperes from DC up to 10 MHz. This paper presents an argument for this equipment as well as the implementation of the HOKA principle applied to merge a four GMR sensors arrangement signal with the output of a 40 winding air coil. Before discussing measurements, each signal path and the evaluation circuit is described in detail.
منابع مشابه
Realization of Novel Cascadable Current-Mode All-pass Sections
This paper introduces four new resistorless circuits of first-order current-mode all-pass filter (CMAPF) based on dual-X current conveyor transconductance amplifier (DXCCTA). All the four circuits use a single DXCCTA and a capacitor for their realization. The main features of the proposed CMAPFs are: use of minimum active and passive components, resistorless realization, electronically adjustab...
متن کاملSpatial detection of ferromagnetic wires using GMR sensor and based on shape induced anisotropy
The purpose of this paper is to introduce a new technique for row spacing measurement in a wire array using giant magnetoresistive (GMR) sensor. The self-rectifying property of the GMR-based probes leads to accurately detection of the magnetic field fluctuations caused by surface-breaking cracks in conductive materials, shape-induced magnetic anisotropy, etc. The ability to manufacture probes h...
متن کاملA New ZVZCS Isolated Dual Series Resonant DC-DC Converter with EMC Considerations
A novel ZVZCS isolated dual series-resonant active-clamp dc–dc converter is proposed to obtain high efficiency. The proposed converter employs an active-clamp technique, while a series-resonant scheme controls the output voltage with the complementary pulse width modulation controller. The active-clamp circuit serves to recycle the energy stored in the leakage inductance or the magnetizing ...
متن کاملInfluence of O2 and N2 Concentrations on the Characteristics of Plasma in DC Cylindrical Magnetron Discharge by Langmuir Probe
Using the Langmuir probe method, the reactive plasma parameters were studied in different ratios of oxygen and nitrogen concentrations in a DC cylindrical discharge device.The plasma parameters such as plasma potential, electron density and electron temperature wereextracted from the current-voltage characteristic’s curve of Langmuir probe to find the optimum conditions for deposit the oxy...
متن کاملA Novel Control Strategy for a Single-phase Grid-connected Power Injection System
In this paper, a novel and simple control strategy, based on state feedback method is suggested to control the power injection system (PIS). The considered PIS is composed of, a DC voltage source, a voltage source inverter (VSI) and a L-C-L filter. The DC source includes the battery source with boosted voltage. The battery can be charged with photovoltaic cells. Since, the grid voltage acts as ...