An In - HouseOpiate EnzymoimmunoassayBased on the Syva EMIT # { 174 } Principle
نویسندگان
چکیده
Many laboratories involved in drug-abuse screening use enzymoimmunoassays such as Syva’s EMIT#{174} system. Although automation has been extensively used to reduce assay costs, further reductions can be achieved by the development of in-house reagents. We have developed our own reagents for the detection of opiates in urine by using the Syva EMIT principle and adapted it for use on an Eppendorf EPOS analyzer. The immunogen was produced from 3-carboxymethylmorphine, and morphine-3glucuronide attached to glucose-6-ptiosphate dehydrogenase was used as the tracer. Excellent agreement with Syva’s commercial assays was obtained.
منابع مشابه
Lowering the federally mandated cannabinoid immunoassay cutoff increases true-positive results.
Proposed changes to the Health and Human Services Guidelines for forensic urine drug testing will lower the required cannabinoid immunoassay cutoff concentration from 100 to 50 micrograms/L. We investigated the effect of this change on the sensitivity, specificity, and efficiency of eight cannabinoid immunoassays: Syva Emit d.a.u. 100; Syva Emit II 100; Syva Emit d.a.u. 50; Syva Emit II 50; Roc...
متن کاملAdaptation of the EMIT serum digoxin assay to a mini-disc centrifugal analyzer.
We have modified the EMIT (Syva) serum digoxin assay for use with a mini-disc centrifugal analyzer. A minicomputer is used to control data acquisition, calculations, and readout for 14 cuvettes simultaneously. Thus, it is not necessary for time each individual assay manually or to plot calibration curves on graph paper. We use incubation times and dilutions similar to those used for the manual ...
متن کاملDrug concentrations, not absorbance units, required for comparing precisions of different immunoassays.
The challenge faced by users of toxicology reagents in performing and interpreting performance comparisons between commercially available methods is routinely complicated by the differences in assay design features offered by reagent manufacturers. Variables such as assigned calibrator concentrations, dynamic range of assay response measurement, and instrument type contribute to the difficulty ...
متن کاملAnalytical Performance Evaluation of EMIT#{174} II Monoclonal Amphetamine/ Methamphetamine Assay: More Specificitythan EMIT#{174} d.a.u.TMMonoclonal Amphetamine/Methamphetamine Assay
We evaluated a new EMIT#{174} II monoclonal amphetamine! methamphetamine assay for screening human urine by comparing itwith the EMIT#{174} d.a.u. monoclonal amphetamine/methamphetamine assay and a fluorescence polarization assay. The EMIT II assay has a cutoff of 1 mg!L d-methamphetamine. The EMIT II and EMIT d.a.u. assays were run on a BM/Hitachi 704 analyzer; for the fluorescence polarizatio...
متن کاملStability of standard curves prepared for EMIT homogeneous enzyme immunoassay kits stored at room temperature after reconstitution.
We examined the stability of standard curves obtained with use of homogeneous enzyme immunoassay reagents (EMIT; Syva Corp., Palo Alto, CA) for assay of lidocaine, procainamide, N-acetylprocainamide, gentamicin, and theophylline, when stored at room temperature (23-24 degrees C) after reconstitution of the lyophilized materials. Standards were run and curves obtained for as long as 16 days afte...