Comparison of supraintercondylar and supracondylar femur fractures treated with condylar buttress plates
نویسندگان
چکیده
BACKGROUND Treatment of supraintercondylar (AO/OTA 33-C) and supracondylar (AO/OTA 33-A) femur fractures is generally challenging. Standard treatments include open reduction and internal fixation. However, optimal implants are now being well-defined. This study focus on the comparison between clinical and functional outcomes of fractures treated with condylar buttress plates (CBPs). METHODS We treated 87 patients with supraintercondylar or supracondylar femur fracture from 2004 to 2008, including 30 supraintercondylar and 24 supracondylar fractures treated with CBPs. Both knee and function scores (per Knee Society) were given to clinical and functional outcomes, and concomitant knee function was assessed per Mize criteria. RESULTS Union rate of supraintercondylar fractures was 90 % (27/30) and supracondylar fractures was 91.7 % (22/24) (P = 0.68). In supraintercondylar group, 16.7 % revealed postoperative varus deformity, whereas none in supracondylar group (P = 0.045). Knee Society knee score was 73.6 in supraintercondylar group and 85.5 in supracondylar group (P = 0.009); and function score was 62.5 in supraintercondylar group and 83.1 in supracondylar group (P = 0.023). A satisfactory result based on modified Mize criteria was achieved in 50 % of supraintercondylar fractures and in 79.1 % of supracondylar fractures (P = 0.09). CONCLUSIONS Use of CBPs for supraintercondylar and supracondylar femur fractures treatment led to a high union rate. However, a high rate of varus deformity occurred in patients with supraintercondylar but not supracondylar fractures. Moreover, CBP treatment in patients with supracondylar fractures led to better functional outcomes than those with supraintercondylar fractures.
منابع مشابه
Condylar Buttress Plate for Fixation of Distal Femur Fracture: Functional and Anatomical Evaluation
Background: Distal Femur fractures are one of the common fractures occurring in road traffic accidents. Various modalities are used for fracture of distal femur, one of them is condylar buttress plate. Various studies have claimed better results in surgical management of distal femur fracture. This study was planned to compare two treatment modalities for supracondylar and intercondylar fractur...
متن کاملIs Distal Femur Locking Plate a Superior Implant in Distal Femur Fracture?
In spite of advances in techniques and improvements in surgical implants, confusion still prevails regarding use of specific implants in distal femur fracture. Fractures in the distal femur have posed considerable therapeutic challenges throughout the history of fracture treatment. Most of these surgical failures were due to inadequate fixation of the fracture fragments. The Aim of the study is...
متن کاملSupracondylar-condylar fractures of the femur.
A retrospective study of 34 patients with supracondylar-condylar fractures of the femur admitted to the Alexandra Hospital, Singapore, from January 1979 to December 1983 was carried out. These fractures were surgically treated by AO principles and fixation, and the surgery performed mainly by the two authors. Using strict criteria adopted from Schatzker of Toronto, 1 it was found that 62% of pa...
متن کاملA comparison of locking versus no nlocking plates in distal femur fractures
Background: Comminuted distal femur fractures are associated with a high complication rate and their treatment is difficult. This type of fracture is more common in young people with major trauma and following motor vehicle accidents. In old patients with osteoporosis the fractures are often closed and occur following a minor trauma. The aim of our study was to compare the outcomes and complica...
متن کاملFractures of the distal femur treated with the AO dynamic condylar screw.
We report the results of treatment with the dynamic condylar screw of 21 cases of supracondylar and intercondylar fractures of the femur in patients aged 22 to 91 years. There were two nonunions and no deaths. We found the device easy to use and the good fixation allowed early patient mobilisation.
متن کامل