Slotted surface coil for magnetic resonance imaging at 4T

نویسندگان

  • S. Solis
  • R. Wang
  • D. Tomasi
  • A. O. Rodriguez
چکیده

Synopsis. A slotted surface coil, inspired on the cavity magnetron was developed for magnetic resonance imaging (MRI) at 4T. Imaging tests using a saline phantom demonstrated that the slotted surface coil has deeper RF-sensitivity than the single-loop RF-coil. High quality images of two rats were acquired simultaneously using standard spin-echo pulse sequences, demonstrating that the slotted surface coil can be a good tool for rat images at 4T.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Slotted end-ring volume coil for small animal Magnetic Resonance Imaging at 7T

Introduction. The development of transceiver volume coils for high field MRI is still a very dynamic field of investigation and development. A volume coil based on the high frequency cavity resonator [1] is presented in this paper for whole-body MRI of rodents at 7 Tesla (proton frequency: 299.47 MHz). This coil design has been previously tested on phantoms at 170 MHz (4T for protons) with stan...

متن کامل

Static Coil Design Considerations for the Magnetic Resonance Imaging

One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...

متن کامل

Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance

Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...

متن کامل

Detunable transverse electromagnetic (TEM) volume coil for high-field NMR.

Most high-field MRI systems do not have the actively detuned body coils that are integral to clinical systems operating at 1.5T and lower field strengths. Therefore, many clinical applications requiring homogeneous volume excitation in combination with local surface coil reception are not easily implemented at high fields. To solve this problem for neuroimaging applications, actively detunable ...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005