Stress evaluation was carried out in 26 patients approximately 7 months after aortic valve replacement with Björk-Shiley valves (13 patients) and St. Jude medical valves (13 patients). During isoproterenol infusion (0.3 micrograms/kg/min), cardiac output increased by a factor of 1.5 and aortic valve area decreased by 50% for both valve groups, while transvalvular gradients (rest: 7 +/- 2 vs 10 +/- 5 mm Hg, p greater than 0.05) increased by 42 +/- 18 vs 51 +/- 18 mm Hg (p greater than 0.05), i.e., to levels of moderate aortic stenosis. However, during pacing stress these values progressively decreased with rising heart rates. In other postoperative evaluations that included ergometric stress with isoproterenol and pacing, induced hemodynamic changes after aortic valve replacement were predictable and consistent with regard to both direction and magnitude, and they differed characteristically according to the type of stress used. We conclude that no functional differences between Björk-Shiley and St. Jude medical valves can be claimed. Standardized evaluation with isoproterenol is a sensitive stress test of prosthetic valvular hemodynamics. Because of the apparent magnification of residual obstruction after aortic valve replacement, it has advantages over pacing.
منابع مشابه
Hemodynamic Alterations Induced by Isoproterenol and Pacing After Aortic Valve Replacement with the Bjork-Shiley or St. Jude Medical Prosthesis
Stress evaluation was carried out in 26 patients approximately 7 months after aortic valve replacement with Bjork-Shiley valves (13 patients) and St. Jude medical valves (13 patients). During isoproterenol infusion (0.3 gg/kg/min), cardiac output increased by a factor of 1.5 and aortic valve area decreased by 50% for both valve groups, while transvalvular gradients (rest: 7 ± 2 vs 10 ± 5 mm Hg,...
متن کاملEchocardiographic assessment of left ventricular filling characteristics after mitral valve replacement with the St Jude medical prosthesis.
The major cause of late mortality and morbidity after prosthetic valve replacement is thromboembolism. The nidus for initiation of thrombus formation has been blood metal interfaces, and a new valve--the St Jude prosthesis--has therefore been developed without any metal components. We have assessed echocardiographically in 27 patients the effects of this valve on left ventricular filling charac...
متن کاملUnusual Disc Dislodgement of a Björk-Shiley Valve after Long-term Implantation
https://e-kcj.org A 40-year-old male was admitted to the cardiac care unit (CCU) due to severe pneumonia associated with unstable hemodynamics. Meanwhile, a grade 3–4 systolic murmur was heard at the left lower sternal border. Tracing his history back, he had undergone mitral valve replacement with a Björk-Shiley convexoconcave prosthetic valve (single tilting disc mechanical valve) 25 years be...
متن کاملClosing sounds and related complaints after heart valve replacement with St Jude Medical, Duromedics Edwards, Björk-Shiley Monostrut, and Carbomedics prostheses.
OBJECTIVE To measure the noise produced and related subjective complaints after implantation of four different mechanical heart valve prostheses and to identify further factors related to the patient and prosthesis that influence noise generation and complaints. DESIGN Sound pressure was measured 5 and 10 cm and 1 m from the point of maximal impulse on the body surface by a calibrated meter i...
متن کاملAuscultatory characteristics of normally functioning Lillehei-Kaster, Björk-Shiley, and St Jude heart valve prostheses.
Auscultatory and echocardiographic and phonocardiographic studies were performed on 26 patients who had a total of 11 Lillehei-Kaster, 16 Björk-Shiley, and 18 St Jude heart valve prostheses functioning normally in the aortic or mitral positions or both. With all types and positions of prostheses a distinct closing sound was always detected. It was frequently heard in two parts which, according ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 63 4 شماره
صفحات -
تاریخ انتشار 1981