Photon energy recovery: a method to improve the effective energy resolution of gamma cameras.
نویسندگان
چکیده
UNLABELLED One of the major limitations of gamma cameras is their relatively poor energy resolution. The main practical consequence of this is that the detection of both scattered and unscattered photons in the photopeak energy window, affecting image contrast and resolution, makes the data inconsistent with the assumption of scatter-free projection data in reconstruction and attenuation correction algorithms. Here, we proposed a method to improve the effective energy resolution of scintigraphic acquisitions. This method is called photon energy recovery (PER). METHODS Photon energy recovery is based on a spectral deconvolution analysis and uses iterative recurrent linear regressions. In practice, PER only required splitting the photopeak energy window into several subwindows and did not need list mode acquisitions. The method was fully automated. Photon energy recovery was quantitatively validated on 99mTc planar images using a Monte Carlo simulation and a real phantom and was illustrated by a bone study. RESULTS The Monte Carlo simulation demonstrated that convergence was reached within relatively few (10-15) iterations. Photon energy recovery led to a considerable quantitative improvement because the mean error between the photopeak energy window image and the true unscattered image was equal to 8.72 s.d. (the mean error between one image and the true image was the mean of the differences between the two images; the difference is expressed as several s.d., where s.d. was the square root of the true value), whereas the mean error between the 140-keV PER image and the true unscattered image was only equal to 2.70. Moreover, the true and PER spectra were highly correlated. The real phantom data pointed out that the counts in the 140-keV PER image calculated from the images acquired "with scatter" were not very different from the true counts given by the "scatter-free" reference image. Planar pelvic bone scintigraphy demonstrated the advantages of PER because contrast increased when only unscattered photons were selected. CONCLUSION Photon energy recovery is a stable and automated method that allows recovery of the correct value of the photon energy after a scintigraphic acquisition. Its ability to separate scattered from unscattered events has been quantitatively validated.
منابع مشابه
Appropriate energy window width for gamma camera [Persian]
Introduction: Scatter radiation is one of the major sources of error in nuclear medicine data processing. Different methods of scatter correction have been introduced in order to improve the quality of data. However the best method is to avoid recording of scatter photons in acquisition. The only difference between scattered and non-scattered photons is the energy. Pulse height analyzer i...
متن کاملEvaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom
Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...
متن کاملNew approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras
Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...
متن کاملComparative assessment of the accuracy of maximum likelihood and correlated signal enhancement algorithm positioning methods in gamma camera with large square photomultiplier tubes
Introduction: The gamma cameras, based on scintillation crystal followed by an array of photomultiplier tubes (PMTs), play a crucial role in nuclear medicine. The use of square PMTs provides the minimum dead zones in the camera. The camera with square PMTs also reduces the number of PMTs relative to the detection area. Introduction of a positioning algorithm to improve the spat...
متن کاملOptical simulation and experimental measurement of gamma ray energy spectrum of plastic scintillators with different sizes
The application of large plastic scintillators is widely increasing in the different areas of industry, medicine and security due to technical and economic advantages. One of the main disadvantages of these detectors is the unknown position of Compton edge at gamma ray spectrum. In this research, GEANT4/GATE code has been used to simulate the gamma ray spectrum for different volumes of large pl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 39 3 شماره
صفحات -
تاریخ انتشار 1998