Toward Rapid, High-Sensitivity, Volume-Constrained Biomarker Quantification and Validation using Backscattering Interferometry

نویسندگان

  • Ian R. Olmsted
  • Mohamed Hassanein
  • Amanda Kussrow
  • Megan Hoeksema
  • Ming Li
  • Pierre P. Massion
  • Darryl J. Bornhop
چکیده

Realizing personalized medicine, which promises to enable early disease detection, efficient diagnostic staging, and therapeutic efficacy monitoring, hinges on biomarker quantification in patient samples. Yet, the lack of a sensitive technology and assay methodology to rapidly validate biomarker candidates continues to be a bottleneck for clinical translation. In our first direct and quantitative comparison of backscattering interferometry (BSI) to fluorescence sensing by ELISA, we show that BSI could aid in overcoming this limitation. The analytical validation study was performed against ELISA for two biomarkers for lung cancer detection: Cyfra 21-1 and Galectin-7. Spiked serum was used for calibration and comparison of analytical figures of merit, followed by analysis of blinded patient samples. Using the ELISA antibody as the probe chemistry in a mix-and-read assay, BSI provided significantly lower detection limits for spiked serum samples with each of the biomarkers. The limit of quantification (LOQ) for Cyrfa-21-1 was measured to be 230 pg/mL for BSI versus 4000 pg/mL for ELISA, and for Galectin-7, it was 13 pg/mL versus 500 pg/mL. The coefficient of variation for 5 day, triplicate determinations was <15% for BSI and <10% for ELISA. The two techniques correlated well, ranging from 3-29% difference for Cyfra 21-1 in a blinded patient sample analysis. The label-free and free-solution operation of BSI allowed for a significant improvement in analysis speed, with greater ease, improved LOQ values, and excellent day-to-day reproducibility. In this unoptimized format, BSI required 5.5-fold less sample quantity needed for ELISA (a 10 point calibration curve measured in triplicate required 36 μL of serum for BSI vs 200 μL for ELISA). The results indicate that the BSI platform can enable rapid, sensitive analytical validation of serum biomarkers and should significantly impact the validation bottleneck of biomarkers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of hybridization-induced secondary structure alterations on RNA detection using backscattering interferometry

Backscattering interferometry (BSI) has been used to successfully monitor molecular interactions without labeling and with high sensitivity. These properties suggest that this approach might be useful for detecting biomarkers of infection. In this report, we identify interactions and characteristics of nucleic acid probes that maximize BSI signal upon binding the respiratory syncytial virus nuc...

متن کامل

Label-free quantification of calcium-sensor targeting to photoreceptor guanylate cyclase and rhodopsin kinase by backscattering interferometry

Quantification of protein binding to membrane proteins is challenging and a limited set of methods is available to study such systems. Here we employed backscattering interferometry (BSI), a free-solution label-free method with high sensitivity, to quantify the interaction of neuronal Ca2+-Sensor proteins with their targets operating in phototransduction. We tested direct binding of guanylate c...

متن کامل

Asphalt Pavement Performance Model of Airport Using Microwave Remote Sensing Satellite

The purpose of this study is to build the binary logit model of an airport pavement that could monitor the pavement condition in near real time using microwave remote sensing satellite, then the relationship between the international roughness index (IRI) of an airport and backscattering values from PALSAR images of the ALOS satellite was determined. Total 390 data were used in analysis. This m...

متن کامل

Ophthalmologist-on-a-chip: Fully Integrated Microfluidic Tear Osmolarity and Protein Biomarker Quantification for Dry Eye Stratification

Human tear film fluid offers tremendous potential as a non-invasive diagnostic fluid. However, the use of tear fluid in diagnostic medicine is limited owing to non-standardized collection methodologies and low volume availability. We present a first-reported microfluidic tear fluid biomarker assay which will serve as a foundation for both rapid biomarker validation and point-of-care ocular diag...

متن کامل

Fli'l Hewlett Measurement of Raylelgh Backscattering at 1.55 Urn with a 32 Um Spatial Resolution

Rayleigh backscattering, optical fiber, optical time reflectometry, OTDR, white light interferometry, optical lowcoherence reflectometry Rayleigh backscattering at a wavelength of 1.55 um is measured in standard single-mode fiber with a spatial resol ution of 32 um and a dynamic range of over 30 dB. A minimum reflection sensitivity of -148 dB is the best reported to date using optical low-coher...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 86  شماره 

صفحات  -

تاریخ انتشار 2014