Short and long term variability of the interrupter technique under field and standardised conditions in 3-6 year old children.
نویسندگان
چکیده
BACKGROUND The short and long term variability of the interrupter technique was assessed to determine whether interrupter resistance is a stable individual characteristic over time. The effect of field and standardised measurement conditions on the within-subject variability of the interrupter technique was also examined. METHODS The interrupter technique was studied under field and standardised conditions in children aged 3-6 years. Under field conditions, five investigators performed the measurements using two different measurement devices in random sequence. Both short term (20-30 minutes) and long term variability (median 38 days) were assessed in 32 children. Under standardised conditions, a single investigator conducted all measurements using a single device; the repeated measurements were conducted at the same time of day in a familiar quiet classroom. Long term variability (median 11 days) was estimated in 15 children. Within-subject standard deviations were estimated by analysis of variance with adjustment for the effects of different investigators and measurement devices on within-subject variability under field conditions. RESULTS Under field conditions within-subject standard deviations for short and long term variability were 0.10 kPa/l/s (adjusted 0.10 kPa/l/s) and 0.13 kPa/l/s (adjusted 0.14 kPa/l/s), respectively. Under standardised conditions the within-subject standard deviation for long term variability was 0.10 kPa/l/s. CONCLUSIONS Measurement of interrupter resistance under field conditions only slightly increased the within-subject variability compared with standardised conditions. The results indicate that interrupter resistance is a stable individual characteristic over a period of some weeks.
منابع مشابه
RESPIRATORY PHYSIOLOGY Short and long term variability of the interrupter technique under field and standardised conditions in 3–6 year old children
Background: The short and long term variability of the interrupter technique was assessed to determine whether interrupter resistance is a stable individual characteristic over time. The effect of field and standardised measurement conditions on the within-subject variability of the interrupter technique was also examined. Methods: The interrupter technique was studied under field and standardi...
متن کاملTraffic-related air pollution is related to interrupter resistance in 4-year-old children.
Outdoor air pollution has been associated with decrements in lung function and growth of lung function in school-age children. Lung function effects have not been examined in preschoolers, with the exception of one study on minute ventilation in newborns. Our goal was to assess the relationship between long- and short-term exposure to traffic-related air pollution and interrupter resistance in ...
متن کامل“Short Paper” The Effect of Short Term and Long Term Feeding of Barley Seed with or Without eCG on Reproductive Performance of Goat During Breeding and Out Breeding Seasons
Nutritional and hormonal programs are one of the important ways of improving goat reproductive performance. Therefore, the present study was conducted to investigate the effect of using barley seed and eCG at the same time on the reproductive performance of goat in nomadic breeding conditions. The number of 60 goats of two to three-year-old in the breeding season and 60 goats of three to four-y...
متن کاملInterrupter resistance short-term repeatability and bronchodilator response in preschool children.
UNLABELLED Interrupter resistance (Rint) technique can be easily and successfully performed in preschool children. The establishment of Rint short-term repeatability is essential to interpret any Rint change after a pharmacological intervention. AIMS OF THE STUDY In preschool children with asthma or chronic cough: (1) to assess two indices of short-term repeatability: (a) intra-measurement an...
متن کاملEvaluation of a new interrupter device for measuring bronchial responsiveness and the response to bronchodilator in 3 year old children.
The interrupter technique for measuring airway resistance is non-invasive and convenient, and therefore ideally suited for the assessment of induced changes in airway calibre in preschool children. The aim of this study was to evaluate a commercially available interrupter device (based on Microlab 4000), which calculates the interrupter resistance (Rint) from pressure and flow following a brief...