Accuracy of implant placement using precision surgical guides with varying occlusogingival heights: an in vitro study.

نویسندگان

  • Chanseop Park
  • Ariel J Raigrodski
  • Jacob Rosen
  • Charles Spiekerman
  • Robert M London
چکیده

STATEMENT OF PROBLEM Surgical guides may interfere with effective use of surgical instrumentation during implant placement in the posterior segments where interocclusal distance may be limited. PURPOSE The purpose of this study was to measure and compare the accuracy of posterior implant placement using 3 precision surgical guides with varying occlusogingival heights, and to evaluate the difference in accuracy of implant placement through precision guides as compared to freehand placement. MATERIAL AND METHODS Three groups of surgical guides were fabricated with occlusogingival heights of 4, 6, and 8 mm, respectively. A jig was fabricated to allow for accurate positioning in bone substitute blocks. Ninety implants were placed in the mandibular first molar site on a manikin. Thirty implants (Astra Tech AB) were placed for each group, with 15 through the guide and 15 freehand. Distances between a reference implant and each placed implant were measured at both implant and abutment levels using a coordinate measuring machine. Apex position and angular discrepancy were calculated using the coordinates of the centers of the implant platform and of the occlusal aspect of the abutment. Data was assessed using 2-way ANOVA (alpha=.05). RESULTS Two-way ANOVA demonstrated that guide height did not significantly affect the accuracy of the implant position. The distance from the reference point to the point of measurement was significantly smaller for placement through the guide compared to freehand placement at both implant (P<.001) and abutment levels (P<.001). The angular discrepancy was also significantly smaller for placement through the guide (P<.001). CONCLUSIONS Precision surgical guides with 4-mm occlusogingival height allow placement as accurate as precision guides with 8-mm height. Placement through the guide reproduced the target position more accurately than freehand insertion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy evaluation of computed tomography-derived stereolithographic surgical guides in zygomatic implant placement in human cadavers.

Presurgical planning is essential to achieve esthetic and functional implants. For implant planning and placement, the association of computer-aided design (CAD) and computer-aided manufacturing (CAM) techniques furnishes some advantages regarding tridimensional determination of the patient's anatomy and fabrication of both anatomic models and surgical guides. The goal of this clinical study wa...

متن کامل

بررسی مقایسه‌ای دو سیستم Cone Beam CT به لحاظ دقت اندازه‌گیری خطی محل‌های قراردهی ایمپلنت در مندیبل به‌صورت In Vitro

Background and Objective: There are critical areas in the mandible that should be considered during implant placement such as inferior alveolar canal, mental foramen, and the root of the adjacent tooth. Two-dimensional images obtained from periapical, panoramic, and conventional tomography are considered in the evaluation of implant placement and bone quality. Cone-beam computed tomography (CBC...

متن کامل

Accuracy of computer-assisted implant placement with insertion templates

OBJECTIVES The purpose of this study was to assess the accuracy of computer-assisted implant insertion based on computed tomography and template-guided implant placement. MATERIAL AND METHODS A total of 246 implants were placed with the aid of 3D-based transfer templates in 181 consecutive partially edentulous patients. Five groups were formed on the basis of different implant systems, surgic...

متن کامل

Computer-aided manufacturing technologies for guided implant placement.

Implant treatment increasingly focuses on the reduction of treatment time and postoperative impairment. The improvement of 3D dental diagnosis by ConeBeam computed tomography allows detailed preparation for the surgical placement of dental implants under prosthetic considerations. While the first generation of implant planning software used high-contrast multislice computed tomography, software...

متن کامل

Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement.

PURPOSE To evaluate the clinical outcomes of implants placed using different types of computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guides, including partially guided and totally guided templates, and determine the accuracy of these guides Materials and methods: In total, 111 implants were placed in 24 patients using CAD/CAM surgical guides. After implant insertion, the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of prosthetic dentistry

دوره 101 6  شماره 

صفحات  -

تاریخ انتشار 2009