Evaluation of left ventricular mechanical dyssynchrony in patients with heart failure after myocardial infarction by real-time three-dimensional echocardiography.
نویسندگان
چکیده
OBJECTIVE To evaluate the incidence and prevalence of left ventricular (LV) dyssynchrony in patients with heart failure after myocardial infarction (MI) by real- time three-dimensional echocardiography (RT-3DE), and to investigate the clinical application value of using RT-3DE as a method of providing more detailed information for clinical strategy. METHODS This cross-sectional study was carried out in Renmin Hospital of WuHan University, Hubei Province, China from July 2009 to December 2010. The RT-3DE was performed on 43 patients with chronic heart failure after MI and 30 normal subjects, to analyze LV volume and left ventricular ejection fraction (LVEF), also the LV systolic dyssynchrony index (SDI). RESULTS The dyssynchrony rate of the total MI patients was 83.7%, and was 100% in the severe dysfunction group. The SDI of MI patients was significantly higher than the control subjects (p less than 0.01), and the SDI of those whose LVEF </=35% is obviously higher than the patients whose LVEF ranges from 35-50%. The LVEF was well correlated with SDI (r = -0.84, p less than 0.001) in MI patients. The LV dyssynchrony prevalence was more severe in the anterior MI than the inferior MI. CONCLUSION The LV dyssynchrony occurred more often in patients with cardiac dysfunction after MI, and was well related with the LV systolic function. The RT-3DE could be considered as an effective and informative tool for the evaluation of LV dyssynchrony.
منابع مشابه
Assessment of left ventricular dyssynchrony by real-time three-dimensional echocardiography.
INTRODUCTION AND OBJECTIVES A number of different imaging methods have been proposed as possible tools for assessing left ventricular (LV) mechanical dyssynchrony. The aim of this study was to evaluate the usefulness of real-time three-dimensional echocardiography (RT3DE) for studying LV mechanical dyssynchrony. METHODS In total, 60 individuals underwent RT3DE, including 10 healthy volunteers...
متن کاملImaging Mechanical Dyssynchrony After Myocardial Infarction in Patients With Left Ventricular Dysfunction, Heart Failure, or Both
Background—Mechanical dyssynchrony is considered an independent predictor for adverse cardiovascular outcomes in patients with heart failure. However, its importance as a risk factor after myocardial infarction is not well defined. Methods and Results—We examined the influence of mechanical dyssynchrony on outcome in patients with left ventricular dysfunction, heart failure, or both after myoca...
متن کاملMechanical dyssynchrony after myocardial infarction in patients with left ventricular dysfunction, heart failure, or both.
BACKGROUND Mechanical dyssynchrony is considered an independent predictor for adverse cardiovascular outcomes in patients with heart failure. However, its importance as a risk factor after myocardial infarction is not well defined. METHODS AND RESULTS We examined the influence of mechanical dyssynchrony on outcome in patients with left ventricular dysfunction, heart failure, or both after myo...
متن کاملA device-occluded ductus arteriosus rendered patent by acute dissection involving the main pulmonary artery and the descending aorta.
Scholte AJ et al. Real-time 3-dimensional echocardiography early after acute myocardial infarction: incremental value of echo-contrast for assessment of left ventricular function. Real-time three-dimensional echocardiography: a novel technique to quantify global left ventricular mechanical dyssynchrony. European Association of Echocardiography recommendations for the assessment of valvular regu...
متن کاملAltered left ventricular contraction pattern during right ventricular pacing: assessment using real-time three-dimensional echocardiography.
BACKGROUND Chronic right ventricular apical (RVA) pacing has been associated with increased risk of heart failure and adverse outcome. The acute effects of RVA pacing on three-dimensional (3D) ventricular function and mechanical dyssynchrony are not well known. We performed a real-time 3D echocardiographic (RT3DE) study to assess global and regional left ventricular function during RVA pacing. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Saudi medical journal
دوره 33 3 شماره
صفحات -
تاریخ انتشار 2012