Applicability of self-activation of an NaI scintillator for measurement of photo-neutrons around a high-energy X-ray radiotherapy machine.

نویسندگان

  • Genichiro Wakabayashi
  • Akihiro Nohtomi
  • Eriko Yahiro
  • Toshioh Fujibuchi
  • Junichi Fukunaga
  • Yoshiyuki Umezu
  • Yasuhiko Nakamura
  • Katsumasa Nakamura
  • Makoto Hosono
  • Tetsuo Itoh
چکیده

The applicability of the activation of an NaI scintillator for neutron monitoring at a clinical linac was investigated experimentally. Thermal neutron fluence rates are derived by measurement of the I-128 activity generated in an NaI scintillator irradiated by neutrons; β-rays from I-128 are detected efficiently by the NaI scintillator. In order to verify the validity of this method for neutron measurement, we irradiated an NaI scintillator at a research reactor, and the neutron fluence rate was estimated. The method was then applied to neutron measurement at a 10-MV linac (Varian Clinac 21EX), and the neutron fluence rate was estimated at the isocenter and at 30 cm from the isocenter. When the scintillator was irradiated directly by high-energy X-rays, the production of I-126 was observed due to photo-nuclear reactions, in addition to the generation of I-128 and Na-24. From the results obtained by these measurements, it was found that the neutron measurement by activation of an NaI scintillator has a great advantage in estimates of a low neutron fluence rate by use of a quick measurement following a short-time irradiation. Also, the future application of this method to quasi real-time monitoring of neutrons during patient treatments at a radiotherapy facility is discussed, as well as the method of evaluation of the neutron dose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Activation of hip prostheses in high energy radiotherapy and resultant dose to nearby tissue

High energy radiotherapy can produce contaminant neutrons through the photonuclear effect. Patients receiving external beam radiation therapy to the pelvis may have high-density hip prostheses. Metallic materials such as those in hip prostheses, often have high cross-sections for neutron interaction. In this study, Thackray (UK) prosthetic hips have been irradiated by 18 MV radiotherapy beams t...

متن کامل

Preparation of nanocomposite scintillator of ZnS doped with Ag, Cu and AgCu for alpha particle detection

ZnS nanoparticles (NPs) doped with ‎Ag‎, ‎Cu‎, ‎and AgCu were synthesized using hydrothermal‎ ‎method in water solution‎. ‎The NPS are characterized by X-ray diffraction (XRD)‎, ‎energy-dispersive‎ ‎X-ray spectroscopy scanning (EDX)‎, ‎scanning electron‎ ‎microscopy (SEM) and dynamic light scattering (DLS)‎. ‎The produced NPs have approximately hexagonal structure and a cubic zinc blended struc...

متن کامل

Determination of the flux of a neutron radioisotope source through gold activation method

Introduction: In recent years, the use of neutrons has increased in various fields such as medicine and industry. One of the important applications of neutrons is in medical research. Neutrons have greater linear energy transfer than gamma rays and are considered more dangerous radiation. Hence, the detection and determination of neutron dose is a very important and vital issu...

متن کامل

Effect of photo–electron therapy on human neoplastic cells

Background: Cancer is a complex disease with high rate of mortality. At present, Radiation therapy is one of the most common procedures to overcome this situation. The deficiency of conventional method is the lack of fatal dose transmission into the malignant tissue. Hence, uncertain dose may cause regeneration of cancer cells, and relapse of the disease and invasion of the cancer cells to ...

متن کامل

HVL evaluation of orthovoltage X-ray machine using EGSnrc code of simulation

Background: Making use of the orthovoltage machines in Radiotherapy, is one of the routine methods for the treatment of the superficial lesions. In this study, an important determinant of X-ray quality, the HVL (Half Value Layer), has been evaluated. Materials and Methods: The HVLs of a orthovoltage X-ray machine in 120 and 180 kVp are measured, using an empirical method, in which the HVLs are ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiological physics and technology

دوره 8 1  شماره 

صفحات  -

تاریخ انتشار 2015