Influences of ammonia contamination on leaching from air-pollution-control residues.

نویسندگان

  • Zhenzhen Guan
  • Dezhen Chen
  • Thomas Fruergaard Astrup
چکیده

Application of selective non-catalytic reduction systems at municipal solid waste incinerators (MSWIs) often involves over-stoichiometric injection of ammonia into flue gases. Un-reacted ammonia may be deposited on fly ash particles and can ultimately influence the leaching behaviour of air-pollution-control (APC) residues. Batch tests were conducted to investigate the impacts of ammonia levels on leaching of a range of metals (sodium, potassium, calcium, aluminium, chromium, iron, lead, cadmium, copper, nickel and zinc), as well as chloride and dissolved organic carbon (DOC). Specific conductivity was also identified to reflect the soluble components. The results showed that with ammonia concentrations rising from a background level of 4 to 26,400 mg l(-1), the specific conductivity increased by 2-7 times as pH varied from alkaline to acidic values. DOC release was also significantly enhanced with high ammonia levels of 1400 mg l(-1) or higher at pH > 9; however at these high ammonia concentrations, the role of DOC in cadmium, copper, nickel and zinc leaching was negligible. Based on the experimental data, chloride, sodium and potassium were leached at high concentrations regardless of pH and ammonia concentrations. For aluminium, chromium, iron and lead, ammonia had little impact on their leaching behaviour. With respect to cadmium, copper, nickel and zinc, high ammonia concentrations significantly increased leaching in the pH range of 8-12 due to the formation of metal-ammonia complexes, which was also proved in the speciation calculations. However, the overall results suggest that typical levels of ammonia injection in MSWIs are not likely to affect metal leaching from APC residues.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Solidification/stabilisation of air pollution control residues using Portland cement: Physical properties and chloride leaching.

Portland cement (CEMI) was used to solidify air pollution control (APC) residues from an energy-from-waste plant burning municipal solid waste. APC residue/CEMI mixes were prepared with CEMI additions ranging from 0 to 50 weight% (wt%) of total dry mass and water/solids ratios between 0.40 and 0.80. Isothermal conduction calorimetry was used to assess the effect of APC residues on the hydration...

متن کامل

Characteristics of air pollution control residues of MSW incineration plant in Shanghai.

A unique type of waste--air pollution control (APC) residues--has received increasing attention in China since the first large-scale incinerator, Shanghai Yuqiao municipal solid waste (MSW) incineration plant, was installed in the country in 2002. The APC residues of this particular plant are similar to other residues that will be produced in other incineration plants under construction in Chin...

متن کامل

Quasi-dynamic leaching characteristics of polychlorinated dibenzo-p-dioxins and dibenzofurans from raw and solidified waste incineration residues.

Quasi-dynamic leaching characteristics of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from raw and solidified air pollution control (APC) residues were examined via a nine-time multiple leaching test. The effect of injected activated carbon in the APC residues on the PCDD/F leachability was also evaluated. When humic acid solution was used as a leachant, the leaching concentra...

متن کامل

Distribution and leaching of methyl iodide in soil following emulated shank and drip application.

Methyl iodide (MeI) is a promising alternative to methyl bromide in soil fumigation. The pest-control efficacy and ground water contamination risks of MeI as a fumigant are highly related to its gas-phase distribution and leaching after soil application. In this study, the distribution and leaching of MeI in soil following shank injection and subsurface drip application were investigated. Methy...

متن کامل

Treatment of Residues from Air Pollution Control Systems

The residues from air pollution control systems on waste incinerators are typically deemed to be a hazardous material due the potential for leaching of trace metals and salts. As a result, in many countries these residues require special handling, treatment and/or disposal. An innovative technology has been developed to recover useful by-products from these residues and render the remaining res...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Waste management & research : the journal of the International Solid Wastes and Public Cleansing Association, ISWA

دوره 32 12  شماره 

صفحات  -

تاریخ انتشار 2014