NIST mixed stain studies #1 and #2: interlaboratory comparison of DNA quantification practice and short tandem repeat multiplex performance with multiple-source samples.
نویسندگان
چکیده
The Mixed Stain Study 1 (MSS1, Apr.-Nov. 1997) and Mixed Stain Study 2 (MSS2, Jan.-May 1999) evaluated multiplexed short-tandem repeat (STR) DNA typing systems with samples containing DNA from more than one source. These interlaboratory challenge studies evaluated forensic STR measurement, interpretation, and reporting practice using well-characterized samples of very different analytical difficulty. None of the relatively few errors reported in either exercise resulted in a false identification of a reference source; several errors in evaluating the unknown source in three-source samples would hinder matching the profile in any archival database. None of the measurement anomalies reported is associated with any particular STR multiplex; all DNA amplification anomalies are associated with inefficient DNA extraction, inaccurate DNA quantitation, and/or analytical threshold policies.
منابع مشابه
NIST Mixed Stain Study 3: DNA quantitation accuracy and its influence on short tandem repeat multiplex signal intensity.
The Mixed Stain Study 3 (MSS3) interlaboratory challenge exercise evaluated the 2001 performance of STR multiplex DNA typing systems using a set of seven DNA extracts of designed concentration and composition. This initial report focuses on the linkages connecting the measurement of the concentration of DNA ([DNA]) to the observed STR multiplex signal intensities. There is a causal relationship...
متن کاملNIST mixed stain study 3: signal intensity balance in commercial short tandem repeat multiplexes.
Short-tandem repeat (STR) allelic intensities were collected from more than 60 forensic laboratories for a suite of seven samples as part of the National Institute of Standards and Technology-coordinated 2001 Mixed Stain Study 3 (MSS3). These interlaboratory challenge data illuminate the relative importance of intrinsic and user-determined factors affecting the locus-to-locus balance of signal ...
متن کاملResults from the NIST 2004 DNA Quantitation Study.
For optimal DNA short tandem repeat (STR) typing results, the DNA concentration ([DNA]) of the sample must be accurately determined prior to the polymerase chain reaction (PCR) amplification step in the typing process. In early 2004, the National Institute of Standards and Technology (NIST) conducted an interlaboratory study to help assess the accuracy of DNA quantitation in forensic DNA labora...
متن کاملRapid quantification of DNA samples extracted from buccal scrapes prior to DNA profiling.
DNA samples within our laboratory are routinely quantified to ensure that the optimal amount of DNA is analyzed by fluorescence-based multiplex analysis of amplified short tandem repeat (STR) loci. Routine quantification is by a dot blot hybridization assay using a probe complementary to the human D17Z1 locus (5,6), and 2 ng of human chromosomal DNA are added to the polymerase chain reaction (P...
متن کاملValidation of a short tandem repeat multiplex typing system for genetic individualization of domestic cat samples.
AIM To conduct developmental validation studies on a polymerase chain reaction (PCR) based short tandem repeat (STR) multiplex typing system, developed for the purpose of genetic individualization and parentage testing in domestic cat samples. METHODS To evaluate reproducibility of the typing system, the multiplex was amplified using DNA extracted from hair, blood, and buccal samples obtained...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of forensic sciences
دوره 46 5 شماره
صفحات -
تاریخ انتشار 2001