Small acoustic neuromas: detection by high resolution gas CT cisternography.
نویسندگان
چکیده
Experience with 81 gas computed tomography (CT) cisternography procedures in 79 patients in searching for acoustic neuroma is reported. Twenty-one tumors, four exclusively intracanalicular, were demonstrated after standard contrast-enhanced CT was negative. Fifty-five examinations were negative; four were inconclusive. The high resolution scanner with digital localization and reconstruction zoom capability greatly improved image detail. In nine of the 12 normal patients examined with it, the intracanalicular bundle was demonstrated. Substitution of carbon dioxide for air greatly reduced the morbidity of acute post-spinal tap headache. The procedure takes 30--45 min and can be performed on an outpatient basis. It is recommended as the procedure of choice when standard CT is negative in subjects clinically suspected of having acoustic neuroma.
منابع مشابه
Air-CT cisternography and canalography for small acoustic neuromas.
Disenchantment with the limitations, and in some cases the morbidity, of currently used radiologic techniques for the demonstration or exclusion of small acoustic neuromas prompted development of an examination using small amounts of intrathecal air and computed tomography (CT). A prospective study was designed to evaluate air CT cisternography/canalography, wherein patients with the clinical s...
متن کاملArachnoiditis simulating acoustic neuroma on air-CT cisternography.
Routine thin-sect ion CT after contrast enhancement may fail to demonstrate smal l acoustic neuromas, usually those smaller than 10 mm [1, 2]. Metrizamide CT cisternography has demonstrated such small acoustic neuromas, but cannot demonstrate an intracanalicular tumor accurately [3]. Pantopaque c isternography can demonstrate an intracanalicular mass, but has a high percentage of inconclusive e...
متن کاملAir CT cisternography of anterior inferior cerebellar artery loop simulating an intracanalicular acoustic neuroma.
Acoustic neuromas larger than 1 cm are usually apparent on routine computed tomography (CT) after contrast enhancement, but smaller lesions escape detection [1, 2]. Metrizamide CT cisternography can demonstrate small lesions, but it is not accurate for the detection of intracanalicular lesions [1, 3]. Pantopaque meatocisternography can detect intracanalicular lesions but has a high percentage o...
متن کاملCT in Diagnosis of Acoustic Neuromas 645
A detailed analysis of the CT findings in 75 cases of acoustic neuroma is presented. The method of examination included plain and enhanced CT, metrizamide CT cisternography (M-CTC), and gas CT cisternography (gas-CTC). The common CT appearances of acoustic neuromas were as follows: 93.6% appeared as isodense or hypodense on precontrast scan; homogeneous enhancement was observed in 53.8% on post...
متن کاملMR imaging of the acoustic nerves and small acoustic neuromas at 0.6 T: prospective study.
To evaluate the capability of magnetic resonance (MR) in imaging normal acoustic nerves, 12 volunteers without signs or symptoms of intracranial disease were examined using a 0.6 T superconductive system. Several spin-echo (SE) pulse sequences were tested to identify the optimal sequence for demonstration of the acoustic nerve bundle. Repetition times (TRs) varied from 300 to 2000 msec and echo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJR. American journal of roentgenology
دوره 139 1 شماره
صفحات -
تاریخ انتشار 1982