A SEM evaluation of debris removal from endodontic files after cleaning and steam sterilization procedures.
نویسندگان
چکیده
BACKGROUND In recent times, it has been proposed to classify endodontic files as single-use items due to a perceived inability to adequately clean the instruments. The purpose of the present study was to quantify the surface debris on files removed from the manufacturer's packaging, and after cleaning using an ultrasonic bath or a thermal disinfector. METHODS Stainless steel and rotary nickel-titanium files were examined after removal from the manufacturer's packaging, after instrumentation in broth-contaminated human teeth, and after various cleaning procedures. The cleaning procedures consisted of either a thermal disinfector cycle, ultrasonication with the files placed in a perforated container or ultrasonication with the files loosely placed in a beaker. The presence of manufacturing debris and biological debris was evaluated using scanning electron microscopy and quantified using image analysis software. RESULTS The effectiveness of cleaning was not affected by variation in the size or taper of the files when an effective cleaning procedure was used. Cleaning the files in a thermal disinfector or by ultrasonication within a container did not consistently achieve complete removal of biological debris. Placing the files loosely in the ultrasonic bath achieved the most effective cleaning, an average of 98.33 per cent of the file surface area was freed of any biological debris. CONCLUSIONS A conventional cleaning method is capable of effectively removing biological debris from endodontic files. The efficacy of ultrasonic cleaning was impaired when the files were placed within a perforated container.
منابع مشابه
Microbiological evaluation of endodontic files after cleaning and steam sterilization procedures.
BACKGROUND Infection control procedures are essential for modern dental practice and they are continually evolving to meet the dental profession's high standards. The present study evaluated the efficacy of two cleaning procedures to reduce bacterial numbers on endodontic files, and evaluated the effect of biological debris on the subsequent sterilization of files. METHODS Stainless steel and...
متن کاملA cleaning protocol for rotary nickel-titanium endodontic instruments.
BACKGROUND The cleaning of endodontic and all dental instruments prior to sterilization is a prerequisite for their processing for re-use. This study aimed to develop a clinically practical cleaning protocol for rotary nickel-titanium (NiTi) endodontic files prior to sterilization. METHODS Cleaning experiments were conducted on six different types of files that had been used on human teeth. T...
متن کاملA comparative study of the cleaning effect of various ultrasonic cleaners on new, unused endodontic instruments
BACKGROUND AND AIM: This study was carried out to compare three different ultrasonic cleaner devices in the cleaning process of endodontic instruments by scanning electron microscope (SEM). METHODS: In this study, 120 unused brand new hand and rotary instruments were examined after removing from the sealed package. The instruments were randomly divided into six groups of 20 rotary or hand files...
متن کاملResidual protein levels on reprocessed dental instruments.
Reduction of the initial bioburden on instruments, prior to sterilization, is believed to reduce transmission risks of iatrogenic Creutzfeldt-Jakob disease. Endodontic files are used in the preparation of root canals and are likely to have close contact and become contaminated with neural material from branches of the maxillary and mandibular cranial nerves. This study examined methods used by ...
متن کاملThe effect of pre-soaking and time in the ultrasonic cleaner on the cleanliness of sterilized endodontic files.
AIMS To assess whether pre-soaking files in an enzymatic cleaner prior to ultrasonic cleaning had any effect on cleanliness and also to assess the effect of the time that endodontic files spend in an ultrasonic bath prior to sterilization on their overall cleanliness. METHODOLOGY Twenty root canals in a total of ten patients were cleaned and shaped using conventional techniques. Following use...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Australian dental journal
دوره 49 3 شماره
صفحات -
تاریخ انتشار 2004