Three-dimensional stereotactic surface projection of brain perfusion SPECT improves diagnosis of Alzheimer's disease.
نویسندگان
چکیده
OBJECTIVES Alzheimer's disease (AD) is diagnosed by either inspection of the brain perfusion SPECT, or three-dimensional stereotactic surface display (3D-SSP). The purpose was to compare diagnostic performances of these methods. METHODS Sixteen nuclear medicine physicians independently interpreted 99mTc-ECD SPECT in one session and SPECT with 3D-SSP in another session without clinical information for 50 studies of AD patients and 40 studies of healthy volunteers. Probabilities of AD were reported according to a subjective scale from 0% (normal) to 100% (definite AD). Receiver operating characteristics curves were generated to calculate areas under the ROC curves (Az's) for the inspection as well as for an automated diagnosis based on a mean Z value in the bilateral posterior cingulate gyri in a 3D-SSP template. RESULTS Mean Az for visual interpretation of SPECT alone (0.679 +/- 0.058) was significantly smaller than that for visual interpretation of both SPECT and 3D-SSP (0.778 +/- 0.060). Az for the automated diagnosis (0.883 +/- 0.037) was significantly greater than that for both modes of visual interpretation. CONCLUSIONS 3D-SSP enhanced performance of the nuclear medicine physicians inspecting SPECT. Performance of the automated diagnosis exceeded that of the physicians inspecting SPECT with and without 3D-SSP.
منابع مشابه
The diagnostic difference between 18F- FDG PET and 99mTc-HMPAO SPECT perfusion imaging in assessment of Alzheimer's disease
Introduction:Brain imaging with F-18 fluorodeoxyglucose (18F-FDG) positron emission tomography or Tc-99m hexamethylpropyleneamine oxime (99mTc-HMPAO) SPECT is widely used for the evaluation of Alzheimer's dementia (AD); we aim to assess superiority of one method over the other. Methods: Twenty four patients with clinical diagnosi...
متن کاملPredicting human performance by channelized Hotelling observer in discriminating between Alzheimer's dementia and controls using statistically processed brain perfusion SPECT.
OBJECTIVE We compared the diagnostic accuracy achieved by a human observer (nuclear medicine physician) and a channelized Hotelling (CH) observer on the basis of receiver-operating characteristics (ROC) curve for the differential diagnosis of Alzheimer's disease (AD) from SPECT images. METHODS The I-123-IMP brain perfusion SPECT images of 42 subjects (21 AD patients and 21 healthy controls) w...
متن کاملThree-dimensional stereotactic surface projection in the statistical analysis of single photon emission computed tomography data for distinguishing between Alzheimer’s disease and depression
AIM To evaluate usefulness of single photon emission computed tomography (SPECT) with three-dimensional stereotactic surface projection (3D-SSP) in distinguishing between Alzheimer's disease (AD) and depression. METHODS We studied 43 patients who presented with both depressive symptoms and memory disturbance. Each subject was evaluated using the following: (1) the Minimal Mental State Examina...
متن کاملCerebral perfusion pattern of idiopathic normal pressure hydrocephalus studied by SPECT and statistical brain mapping.
OBJECTIVES To investigate the specific pattern of cerebral blood flow (CBF) in subjects with idiopathic normal pressure hydrocephalus (iNPH) using voxel-based analysis. METHODS N-isopropyl-p-[123I]iodoamphetamine (IMP) single photon emission computed tomography (SPECT) images were performed in 30 iNPH patients, who met probable iNPH criteria, 30 Alzheimer disease (AD) patients and 15 normal c...
متن کاملSuperiority of 3-dimensional stereotactic surface projection analysis over visual inspection in discrimination of patients with very early Alzheimer's disease from controls using brain perfusion SPECT.
UNLABELLED In Alzheimer's disease (AD), regional cerebral blood flow (rCBF) in the posterior cingulate gyri and precunei has been reported to decrease even at a very early stage. It may be helpful to use statistical image analysis to distinguish slight decreases in rCBF in this area. We compared a 3-dimensional stereotactic surface projection (3D-SSP) technique with visual inspection in the dis...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of nuclear medicine
دوره 17 8 شماره
صفحات -
تاریخ انتشار 2003