Tolerance and Safety of 5 Models of Sedation During Endobronchial Ultrasound.

نویسندگان

  • Enrique Cases Viedma
  • Felipe Andreo García
  • Javier Flandes Aldeyturriaga
  • Juan Pablo Reig Mezquida
  • Andrés Briones Gómez
  • Pere Vila Caral
  • Iker Fernández-Navamuel Basozabal
  • Carmen Ángela Centeno Clemente
  • Felipe Campo Campo
  • Estefanía Sánchez Martínez
  • Francisca Sanchis Moret
  • Josefina Manjón Pérez
  • Marina Sánchez Yepes
چکیده

INTRODUCTION Sedation during endobronchial ultrasound (EBUS) is essential due to the long duration of this procedure. We evaluated different models of sedation and their complications. METHOD A multicenter, prospective, observational study of 307 patients undergoing EBUS was conducted. Patients were sedated with: a) midazolam bolus; b) propofol infusion; c) midazolam bolus and propofol infusion; d) propofol infusion and remifentanil infusión, or e) midazolam bolus and fentanyl bolus, and clinical variables were collected. Patients were asked to complete a satisfaction survey following the test. RESULTS Patients per sedation model were: A 24, B 37, C 107, D 62 and E 77. Scores for perceived sensations of recall, pain, cough, dyspnea and prolonged examination (0.65±1.11; 0 3±0.73, 0.46±0.9, 0.29±0.73, and 0.59±0.96, respectively) were lower compared to fear and nervousness before the examination (1.26±1.37 and 1.5±1.41, respectively). High levels of indifference to repeating the procedure (1.49±1.3) and a reported pleasant feeling during the test (1.23±1.17), with low levels of anxiety (0.49±0.85) and discomfort (0.62±1.1), show that different models of sedation were well tolerated. Almost half the patients (46.6%) did not report any "worst moment" during the procedure, and 89.6% were willing to undergo a repeat test. The E and C models presented fewest complications (12.9 and 31.7%, respectively), and all were resolved with simple therapeutic measures. CONCLUSIONS The models of sedation evaluated were well tolerated and most patients were willing to undergo repeat EBUS. Complications were few and easily resolved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radial Probe Endobronchial Ultrasound for Peripheral Pulmonary Lesions: Initial Experience in an Indian Tertiary Healthcare Centre

Introduction : Diagnosis of peripheral pulmonary nodules is confusing; therefore, an accurate and safe lung biopsy can prevent unnecessary invasive diagnostic procedures. This study soughtto study the diagnostic yield, sensitivity, specificity, and negative and positive predictive values (NPV and PPV) of radial probe endobronchial ultrasound (EBUS)-guided biopsy for peripheral pulmonary lesions...

متن کامل

The role of sedation in endobronchial ultrasound-guided transbronchial needle aspiration: Systematic review

BACKGROUND Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive procedure that has become an important tool in diagnosis and staging of mediastinal lymph node (LN) lesions in lung cancer. Adequate sedation is an important part of the procedure since it provides patient's comfort and potentially increases diagnostic yield. We aimed to compare deep ...

متن کامل

Patient satisfaction during endobronchial ultrasound-guided transbronchial needle aspiration performed under conscious sedation.

BACKGROUND Mediastinal and hilar lymph node evaluation with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is being performed with increasing frequency. Original reports described performance under general anesthesia. Patient satisfaction is an important determinant of whether EBUS-TBNA may be performed under conscious sedation. METHODS Consecutive patients under...

متن کامل

Impact of sedation technique on the diagnostic accuracy of endobronchial ultrasound-guided transbronchial needle aspiration

BACKGROUND AND OBJECTIVES There is a paucity of data concerning the impact of the sedation technique used for endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) on diagnostic accuracy. The aim of this retrospective study was to compare the diagnostic accuracy of EBUS-TBNA in deep and moderate sedations, and to investigate other possible determinants of diagnostic accur...

متن کامل

Endosonography for mediastinal disease: esophageal ultrasound vs. endobronchial ultrasound

BACKGROUND AND STUDY AIMS One can approach mediastinal pathology via esophageal ultrasound (EUS) and/or endobronchial ultrasound (EBUS). It has been suggested that EUS is better tolerated by patients. If so, EUS might be the procedure of choice when suspect lesions are accessible via EUS. We studied procedural characteristics of EUS with fine needle aspiration (EUS-FNA) and EBUS with transbronc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archivos de bronconeumologia

دوره 52 1  شماره 

صفحات  -

تاریخ انتشار 2016