Experiment on Parameter Selection of Image Distortion Model
نویسندگان
چکیده
Most of current camera calibration methods for a non-metric digital camera adopt polynomials of image coordinates composed of terms representing the correction to the principal distance, the offsets of the principal point, the radial lens distortion, and the decentering lens distortion of the target camera as the image distortion model. However, there is no standard procedure to evaluate appropriateness of parameter selection of the image distortion model. Therefore, we conducted a field experiment on parameter selection of the ordinary image distortion model widely used for camera calibration. We adopted a calibration method using a set of calibration points distributed on the 2-D plane with no ground survey. Four non-metric digital cameras were calibrated in the filed experiment. 16 rounds of camera calibration for six different parameter sets of the image distortion model were conducted. Evaluation of calibration results was performed by differences of image distortions calculated at all pixels on image between the obtained image distortion models. The experiment results indicate that the adoption of the decentering lens distortion component has the significant influence on the estimation of the distribution of image distortion, even if the magnitude of the decentering lens distortion component is small.
منابع مشابه
Just Noticeable Difference Estimation Using Visual Saliency in Images
Due to some physiological and physical limitations in the brain and the eye, the human visual system (HVS) is unable to perceive some changes in the visual signal whose range is lower than a certain threshold so-called just-noticeable distortion (JND) threshold. Visual attention (VA) provides a mechanism for selection of particular aspects of a visual scene so as to reduce the computational loa...
متن کاملImaging Analysis of Space Target in Bistatic ISAR
Abstract. Bistatic angle is an important characteristic parameter of bistatic inverse synthetic aperture radar (ISAR), which is different from monostatic ISAR. Based on the echo model of bistatic ISAR, the impact of time-varying bistatic angle to imaging plane and quality is analyzed. The image distortion mechanism is studied and the distortion angle is estimated. The simulation experiment veri...
متن کاملWhat accuracy for 3D measurements with cameras?
We estimate the internal and external parameters of the camera, and simultaneously the distortion S parameters. Our aim is the selection of the best distortion model, using stiatistical test for the importance of distortion parameters. Also we examine the accuracy in camera parameter estimation and 30 reconstruction, in relation with the noise in the image. We answer the question “until which l...
متن کاملVision model based video perceptual distortion measure for video processing and applications
In this paper a perceptual video distortion measure system based on the human vision model is presented. This system is an extension of the still perceptual distortion measure system. One advantage of the distortion measure is that the distortion can be weighted for frames in the vicinity of scene cuts. Our video distortion measure also requires less computation compared to other approaches. Th...
متن کاملDesign, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems
Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...
متن کامل