Quantitative Assessment of Air Trapping Using Inspiratory and Expiratory Low-Dose Computed Tomography
نویسندگان
چکیده
Objective: The purpose of this study was to evaluate the effect of radiation dose reduction on the quantification of air trapping on expiratory CT. Materials and methods: This study was conducted as a retrospective evaluation of inspiratory and expiratory CT studies performed in routine clinical practice before and after alteration of the scanning protocol for expiratory CT at our institute. Eighty-six patients who had a clinical diagnosis of chronic obstructive pulmonary disease (COPD) and underwent inspiratory and expiratory CT and pulmonary function testing (PFT) were included. For the quantitative analysis, CT scans were obtained at six evenly spaced levels from the lung apices to the bases. The area of segmented lung without emphysema between −500 to −950 HU was obtained from the summation of six slices. The relative area between −900 and −950 HU for the area of the segmented lung (RA900-950) was calculated on both the inspiratory and expiratory scans. Comparisons of the RA-change between the standard-dose group (200 mA) and the low-dose group (80 mA) were performed by Mann-Whitney U test. Results: There was no significant difference between the standard-dose group and the low-dose group in the mean RA-change, and RA-change in both the standard-dose and low-dose groups correlated significantly with the results of PFT. In addition, there were no prominent differences in the correlation coefficients between the two groups. Conclusions: Low-dose CT could evaluate air trapping objectively and was not inferior to standard-dose CT for this purpose.
منابع مشابه
CT Air Trapping Is Independently Associated with Lung Function Reduction over Time
PURPOSE We aimed to study the association between lung function decline and quantitative computed tomography (CT) air trapping. MATERIALS AND METHODS Current and former heavy smokers in a lung cancer screening trial underwent volumetric low-dose CT in inspiration and expiration. Spirometry was obtained at baseline and after 3 years. The expiratory to inspiratory ratio of mean lung density (E/...
متن کاملQuantitative Assessment of Global and Regional Air Trappings Using Non-Rigid Registration and Regional Specific Volume Change of Inspiratory/Expiratory CT Scans: Studies on Healthy Volunteers and Asthmatics
OBJECTIVE The purpose of this study was to compare air trapping in healthy volunteers with asthmatics using pulmonary function test and quantitative data, such as specific volume change from paired inspiratory CT and registered expiratory CT. MATERIALS AND METHODS Sixteen healthy volunteers and 9 asthmatics underwent paired inspiratory/expiratory CT. ΔSV, which represents the ratio of air fra...
متن کاملApplication of an optical flow method to inspiratory and expiratory lung MDCT to assess regional air trapping: a feasibility study.
OBJECTIVE We describe the application of an optical flow method to inspiratory and expiratory high-resolution volumetric lung MDCT for the assessment of regional air trapping. CONCLUSION Qualitative and quantitative assessment of regional air trapping is feasible using an optical flow method to align volumetric MDCT data sets.
متن کاملPaired inspiratory-expiratory chest CT scans to assess for small airways disease in COPD
BACKGROUND Gas trapping quantified on chest CT scans has been proposed as a surrogate for small airway disease in COPD. We sought to determine if measurements using paired inspiratory and expiratory CT scans may be better able to separate gas trapping due to emphysema from gas trapping due to small airway disease. METHODS Smokers with and without COPD from the COPDGene Study underwent inspira...
متن کاملRelationship between CT air trapping criteria and lung function in small airway impairment quantification
BACKGROUND Small airways are regarded as the elective anatomic site of obstruction in most chronic airway diseases. Expiratory computed tomography (CT) is increasingly used to assess obstruction at this level but there is no consensus regarding the best quantification method. We aimed to evaluate software-assisted CT quantification of air trapping for assessing small airway obstruction and dete...
متن کامل