Glucose pump test: a new method for blood flow measurements.
نویسندگان
چکیده
BACKGROUND A good test for monitoring blood flow (Q(a)) must be accurate, rapid and economical in order to allow frequent easy measurements. The glucose pump test (GPT) is based on a constant glucose infusion as a dilutional indicator of Q(a). METHODS GPT protocol requires a constant glucose infusion, by a syringe pump, into the arterial needle and two blood withdrawals from the venous needle, one basal before the infusion (C(a1)), the other (C(a2)) 11 s after the start of the infusion. At the bedside we measure glucose on C(a1) and C(a2). Knowing the infused glucose concentration (C(i)) and the pump infusion rate (Q(i)) we can easily calculate Q(a)=Q(i)x(C(i)-C(a2))/(C(a2)-C(a1)). We verified the accuracy of this new method by comparing it with the in vitro results from a circuit reproducing vascular access circulation, and in vivo comparing GPT-Q(a) with Doppler ultrasound in pre-dialysis to the Transonic HD01-Q(a) during dialysis in 23 chronic haemodialysis patients. RESULTS GPT-Q(a) values were highly correlated with the in vitro Q(a)=1.01 x GPT-Q(a)-16.6; r=0.94. There was agreement between the mean flow values of GPT and Doppler (927.5 and 927.1 ml/min, respectively; P=NS) while the mean value of HD01 was significantly lower (HD01-Q(a)=690 ml/min; P<0.001 vs GPT-Q(a) and Doppler-Q(a)). The regression analysis showed a good correlation between GPT and Transonic results (r=0.95; HD01-Q(a)=0.86 x GPT-Q(a)-111.9), while there was a significant difference between the two measurements (mean Delta 235+/-117 ml/min; range from 15 to 451 ml/min). This difference could be caused by the large haemodynamic variations (different blood pressure, cardiac output, circulating effective volume, haematocrit) between pre-dialysis and intra-dialysis and in addition by the counter current flow during the reversal blood lines Transonic measurements. CONCLUSIONS GPT offers the advantage of a simple bedside procedure easily performed before dialysis: it does not interfere with the dialysis treatment and it is less intrusive for the patient as it does not involve reversal of the blood lines. The preliminary data indicate that our method could be a useful, simple and cheap test for monitoring access flow in every dialysis unit.
منابع مشابه
Normetanephrine and Glucose Acute Responses to Aerobic Boxing with Kinect Xbox with and without Blood Flow Restriction as a Strategy against Inactivity in Non-Athletes
Background and Aim: Inactivity increases the risk of chronic diseases. The aim of the present study was to investigate the acute changes in Normetanephrine and glucose in boxing with Kinect Xbox with and without blood flow restriction as an alternative to aerobic exercise during quarantine in young non-athletes. Material and Methods: Fourteen healthy non-athlete individuals with a range of 20 ...
متن کاملA Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia
Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of ...
متن کاملمقایسه میزان همخوانی یافتههای سنجش قندخون با استفاده از گلوکومتر ON CALL و گلوکوکارد با روش آزمایشگاهی استاندارد
Background: Diabetes Mellitus (DM) is one the most common chronic disease, with many complications including renal failure, blindness and non traumatic amputation. Prevention of complications is possible through monitoring and control of blood glucose levels. Considering how easy home blood glucose monitoring is, we decided to evaluate the performance of two available glucometers for detection...
متن کاملExperimental Investigation of a New Enthalpy Exchanger with Low Absorbent Carryover Designed for Liquid Desiccant Dehumidification System
In this paper, the absorbent carryover effect in a designed counter-flow enthalpy exchanger is investigated. In a built prototype of the liquid desiccant dehumidifier, air and the absorbent solution are in contact and flow through a packed multi-channel polymer tower in a counter-flow pattern. To avoid the absorbent carryover, the tower is equipped with an eliminator. Experimental measurements ...
متن کاملبررسی همخوانی نوارهای سنجش قند خون بتاچک با روش استاندارد
Diabetes mellitus (DM) is the commonest cause of renal failure, blindness and non traumatic amputation. According to ADA, prevention of DM complications is possible through monitoring and control of blood glucose levels.Methods: The Betachek strip, produced in Australia, is able to determine biood glucose level with no need for electronic glucometer devices.Results: In this study, we compared v...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 17 12 شماره
صفحات -
تاریخ انتشار 2002