Characterization of dose-dependent Young's modulus for a radiation-sensitive polymer gel.

نویسندگان

  • Remo A Crescenti
  • Jeffrey C Bamber
  • Nigel L Bush
  • Steve Webb
چکیده

Radiation-sensitive polymer gels for clinical dosimetry have been intensively investigated with magnetic resonance imaging (MRI) because the transversal magnetic relaxation time is dependent on irradiation dose. MRI is expensive and not easily available in most clinics. For this reason, low-cost, quick and easy-to-use potential alternatives such as optical computed tomography (CT), x-ray CT or ultrasound attenuation CT have also been studied by others. Here, we instead evaluate the dose dependence of the elastic material property, Young's modulus and the dose response of the viscous relaxation of radiation-sensitive gels to discuss their potential for dose imaging. Three batches of a radiation-sensitive polymer gel (MAGIC gel) samples were homogeneously irradiated to doses from 0 Gy to 45.5 Gy. Young's modulus was computed from the measured stress on the sample surface and the strain applied to the sample when compressing it axially, and the viscous relaxation was determined from the stress decay under sustained compression. The viscous relaxation was found not to change significantly with dose. However, Young's modulus was dose dependent; it approximately doubled in the gels between 0 Gy and 20 Gy. By fitting a second-order polynomial to the Young's modulus-versus-dose data, 99.4% of the variance in Young's modulus was shown to be associated with the change in dose. The precision of the gel production, irradiation and Young's modulus measurement combined was found to be 4% at 2 Gy and 3% at 20 Gy. Potential sources of measurement error, such as those associated with the boundary conditions in the compression measurement, inhomogeneous polymerization, temperature (up to 1% error) and the evaporation of water from the sample (up to 1% error), were estimated and discussed. It was concluded that Young's modulus could be used for dose determination. Imaging techniques such as elastography may help to achieve this if they can provide a local measurement of Young's modulus, which may eliminate problems associated with the boundaries (e.g. variation in coefficient of friction) and inhomogeneous polymerization. Elastography combined with a calibration should also be capable of mapping dose in three dimensions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Ability of Ultrasonic Characterization to Extract the Dose Distribution of MAGIC-f Polymer Gel

Background & Aims: Today, different imaging techniques have been studied in the reading of radiationsensitive polymer gels dosage. Due to limitations of imaging techniques such as magnetic resonance imaging (MRI) and computed tomography (CT), ultrasound techniques are proposed for dose-dependent parameter extraction. In this study, using MAGIC-f (methacrylic and ascorbic acid in gelatin initiat...

متن کامل

Optical Characterization of NIPAM and PAGAT Polymer Gels for Radiation Dosimetry

Introduction The purpose of the current study was to determine optical sensitivity of N-isopropyl acrylamide NIPAM and polyacrylamide gelatin and tetrakis hydroxymethyl phosphoniun chloride (PAGAT) polymer gels for different wavelength of visible light spectrum applied in optical computed tomography method. Materials and Methods NIPAM and PAGAT polymer gels with conventional formulations used f...

متن کامل

Dose enhancement effect of gold nanoparticles on MAGICA polymer gel in mega voltage radiation therapy

Background: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like developed to date. Among the special features of this type of dosimeters, is be doped with other elements or chemicals which made them appropriate for investigating of dose enhancement with contrast agents, by high atomic number. Material and Methods: In this study...

متن کامل

Evaluation of Gold Nanoparticle Size Effect on Dose Enhancement Factor in Megavoltage Beam Radiotherapy Using MAGICA Polymer Gel Dosimeter

Background: Gold nanoparticles (GNPs) are among the most promising radiosensitive materials in radiotherapy. Studying the effective sensitizing factors such as nanoparticle size, concentration, surface features, radiation energy and cell type can help to optimize the effect and possible clinical application of GNPs in radiation therapy. In this study, the radiation sensitive polymer gel was use...

متن کامل

Small field size dose-profile measurements using MAGIC- f polymer gel dosimeter and EBT3 film dosimeter

Introduction: In radiotherapy, treatment planning methods are evaluating and transforming every day, so precision in calculation and determination of dose delivery process is performing more important role in radiotherapy than past. In modern radiotherapy treatments, deramatically increase of small fields utilization, causes the polymeric gels has known as the most reliable dos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 54 4  شماره 

صفحات  -

تاریخ انتشار 2009