Adaptive Under-Frequency Load Shedding Scheme in System Integrated with High Wind Power Penetration: Impacts and Improvements

نویسندگان

  • Shun Li
  • Fei Tang
  • Youguo Shao
  • Qingfen Liao
چکیده

As the requirements of economical operation and reliability on power grid are enhanced gradually nowadays, the existing under frequency load shedding (UFLS) scheme is not quite fit for the modern power system that integrates high wind power. In this paper, the impacts of high wind power penetration on the UFLS are discussed thoroughly. A novel adaptive load shedding (LS) scheme is presented taking the high wind power penetration into account. In the proposed scheme, the equivalent inertia constant (EIC) is calculated accurately to improve the power deficit accuracy so as to reduce the error of LS. The dynamic correction of power deficit is able to solve the negative effects of the wind power output random reduction/the wind generator tripping. Besides, the locking criterion is capable of avoiding the influences of the wind power output random increase on the LS, thus cutting down the LS costs and even preventing the frequency overshoot. Moreover, in terms of the LS parameters setting, the coordination of the low frequency protection of the wind generator and the frequency threshold is addressed. The location and capacity model of LS, which is based on the load characteristics, can ameliorate the frequency recovery process. Finally, the validity and robustness of the proposed scheme are verified in the simulations on the IEEE-39 bus system with high wind power penetration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhancement of Power System Voltage Stability Using New Centralized Adaptive Load Shedding Method

This paper presents a new centralized adaptive method under frequency load shedding. Sometimes, after initial frequency drop following severe disturbances, although the system frequency returns to its permissible value, however, the system might become unstable due to voltage problems. In this regard, the paper proposes a new centralized adaptive load shedding method to enhance the voltage stab...

متن کامل

Coordinated Control of Doubley Fed Induction Generator Virtual Inertia and Power System Oscillation Damping Using Fuzzy Logic

Doubly-fed induction generator (DFIG) based wind turbines with traditional maximum power point tracking (MPPT) control provide no inertia response under system frequency events. Recently, the DFIG wind turbines have been equipped with virtual inertia controller (VIC) for supporting power system frequency stability. However, the conventional VICs with fixed gain have negative effects on inter-ar...

متن کامل

ارائه الگوریتم حذف بار وفقی جهت حفاظت سیستم قدرت در مقابل حوادث ترکیبی منجر به خاموشی سراسری

In recent years several catastrophic power systems blackouts have occurred worldwide. Various reasons have been declared for these failures. Economical limitations due to power system restructuring restrictions, inadvertent operation of protective relays and inefficient design of conventional load shedding schemes are of the most important reasons causing these blackouts. In fact, due to both e...

متن کامل

An Improved Under-Frequency Load Shedding Scheme in Distribution Networks with Distributed Generation

When a distribution network consisting of Distributed Generations (DGs) is disconnected from upstream network, the system may be exposed to severe power imbalance. In order to prevent the damage of power plants, frequency relays operate and remove DGs from the network. In contrast to traditional methods, the main objective in new methods is to keep DG units in service in the islanded distributi...

متن کامل

A New Adaptive Load-Shedding and Restoration Strategy for Autonomous Operation of Microgrids: A Real-Time Study

Islanding operation is one of the main features of a MicroGrid (MG), which is realized regarding the presence of distributed energy resources (DERs). However, in order to deal with the control challenges, which an MG faces during island operation, particularly when the transition is associated with certain excessive load, an efficient control strategy is required. This paper introduces a Centra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017