A two-stage validation study for determining sensitivity and specificity.

نویسندگان

  • T D Tosteson
  • L Titus-Ernstoff
  • J A Baron
  • M R Karagas
چکیده

A two-stage procedure for estimating sensitivity and specificity is described. The procedure is developed in the context of a validation study for self-reported atypical nevi, a potentially useful measure in the study of risk factors for malignant melanoma. The first stage consists of a sample of N individuals classified only by the test measure. The second stage is a subsample of size m, stratified according the information collected in the first stage, in which the presence of atypical nevi is determined by clinical examination. Using missing data methods for contingency tables, maximum likelihood estimators for the joint distribution of the test measure and the "gold standard" clinical evaluation are presented, along with efficient estimators for the sensitivity and specificity. Asymptotic coefficients of variation are computed to compare alternative sampling strategies for the second stage.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mixed two-stage derivative estimator for sensitivity analysis

In mathematical modeling, determining most influential parameters on outputs is of major importance. Thus, sensitivity analysis of parameters plays an important role in model validation. We give detailed procedure of constructing a new derivative estimator for general performance measure in Gaussian systems. We will take advantage of using score function and measure-value derivative estimators ...

متن کامل

Diagnostic Utility of Chest X-rays in Neonatal Respiratory Distress: Determining the Sensitivity and Specificity

Background: Chest radiography is one of the most usual diagnostic tools for respiratory distress. Objective: The purpose of this study is to assess the specificity, sensitivity and clinical value of chest radiography of neonates with respiratory distress.Patients and Methods: A descriptive- analytical study was conducted on 102 neonates that were in neonatal intensive care unit of Imam Reza and...

متن کامل

The validation of one halitosis measuring device (Etiquette checker)‎

BACKGROUND AND AIM: Various measurement devices are available for detection of halitosis. For epidemiologic studies, it is necessary to use a portable and small device. This study aimed to investigation of correlation between measuring the device (Etiquette checker) with Halimeter. METHODS: One hundred volunteers (students and patients) participated in this study. The amount of volatile sulfur ...

متن کامل

Comparison of the Diagnostic Values of Four-Point and Two-point Ultrasound Versus CT Scan in Determining Pneumothorax

Background and Objectives: Pneumothorax is a life-threatening complication and the most common cause of which is trauma. Early diagnosis and treatment of Pneumothorax are very important. The aim of this study was to compare the diagnostic values of four-point and double-point ultrasound versus CT scan in determining pneumothorax in Rasul-Akram and Hafte-Tir Hospitals during the years 2015 - 201...

متن کامل

Comparison sensitivity and specificity temporal artery temperature measurement with axillary and nasopharyngeal methods in adult

      Aims: temporal artery thermometers (TAT) of new tools for measuring body temperature, few studies have been conducted to evaluate the accuracy and reliability of thermometers and is still uncertain accuracy and reliability this thermometers.This study to evaluate the accuracy of the two methods of measuring body temperature by the thermometer axillary and temporal artery compared with nas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Environmental Health Perspectives

دوره 102  شماره 

صفحات  -

تاریخ انتشار 1994