Laparoscopic Bowel Resection: A Comparison of Three Ultrasonically Activated Devices
نویسندگان
چکیده
BACKGROUND AND OBJECTIVES To compare resection time and collateral thermal damage of 3 currently available ultrasonically activated devices in laparoscopic small bowel surgery. METHODS AutoSonix, SonoSurg, and UltraCision were compared in laparoscopic small bowel mesentery resection in a porcine model. A resection was defined as 12 endarcade arteries supplying the intended bowel segment. Vssels were divided 1 cm off the bowel wall. AutoSonix, SonoSurg, and UltraCision were comparable for blade length and type, cutting mechanism, handle ergonomics, and vibration amplitude, but not well matched for vibration frequency (55.5;23.5;55.5 kHz), working shaft diameter (5;11;10 mm) and length (29;33;34 cm), respectively. A sample size of 114 was calculated to detect a 25% difference with 90% power at a 5% significance level. Resections were allocated to devices by block randomization. Analysis of variance and pairwise Scheffe tests were used for multiple comparisons, and a Kaplan-Meier plot was drawn to confirm differences in resection time with each device. A pathologist blind to the devices evaluated bowel wall biopsies for thermal damage. RESULTS Procedures as allocated comprised 114 resections (38 with each device). UltraCision median resection time of 5160 (range 2340-7860) seconds was significantly longer (P=0.0001). The difference in resection time between AutoSonix (median 3420, range 1860-8760 s) and SonoSurg (median 3660, range 1800-6900 s) did not reach statistical significance. A microscopy revealed no thermal damage. CONCLUSIONS Laparoscopic resection time for porcine bowel mesentery was shorter with AutoSonix or SonoSurg than with UltraCision, and no thermal damage to the bowel wall was found.
منابع مشابه
Laparoscopic Intracorporeal Bowel Resection with Ultrasound versus Electrosurgical Dissection
BACKGROUND AND OBJECTIVES We assessed resection time and collateral thermal tissue damage of ultrasonically activated surgery (UAS) and high-frequency blade-enhanced bipolar electrosurgery (BE) in laparoscopic bowel surgery. METHODS We compared UAS laparoscopic intracorporeal small bowel mesentery re-section with an equivalent procedure performed with BE in a porcine model. Resection was defi...
متن کاملLaparoscopic Colon Surgery for Benign Disease: A Comparison to Open Surgery
Backgrounds and Objectives: Today we are witnessed a growing number of minimally invasive surgical techniques for different diseases. Laparoscopic colon surgery as a minimally invasive surgery is currently growing in treatment of malignancies after proving his place in the treatment of benign diseases. We compare in this study results of laparoscopic colorectal surgery with open surgery. Method...
متن کاملLaparoscopic-Assisted Colectomy: A Comparison of Dissection Techniques
BACKGROUND AND OBJECTIVES Mobilization of the colon and dissection of the mesentery are difficult laparoscopic techniques. Traditional methods have been used for this dissection, but often with great difficulty. The ultrasonically activated shears, when introduced in 1993, had the possibility to make this dissection less technically difficult. This is a retrospective review of the use of these ...
متن کاملLaparoscopic Management of Strangulated Broad Ligament Hernia
Introduction: Broad ligament hernia was first reported post-autopsy by Quain in 1861. In a 1995 review article, only 61 cases had ever been reported. This paper presents a case report of broad ligament hernia and explores the literature surrounding this topic. Case Presentation: The patient presented with no significant past medical history, acute lower a...
متن کاملUsefullness of the ultrasonically activated scalpel in laparoscopic cholecystectomy: our experience and review of literature.
Laparoscopic cholecystectomy (LC) actually represents the most used and proper treatment for gallbladder lithiasis, because its many and known advantages in comparison with 'open' abdominal surgery. But there are some problems during and after LC due to the use of the electric scalpel and these have brought to the search of an alternative system of dissection and coagulation. The ultrasonically...
متن کامل