Real-time freehand 3D ultrasound calibration.
نویسندگان
چکیده
Z-fiducial phantoms allow three-dimensional ultrasound probe calibration with a single B-scan. One of the main difficulties in using this phantom is the need for reliable segmentation of the wires in the ultrasound images, which necessitates manual intervention. In this article, we have shown how we can solve this problem by mounting a thin rubber membrane on top of the phantom. The membrane is segmented automatically and the wires can be easily located as they are at known positions relative to the membrane. This enables us to segment the wires automatically at the full PAL frame rate of 25 Hz, to produce calibrations in real-time, while achieving accuracies similar to those reported in the literature. We have also devised a technique to improve the estimation of the elevational offset (calibration parameter) by capturing a few images of the planar membrane. If spatial calibration is known, fully automatic wire segmentation allows the fiducials to be tracked in real-time. This also enables temporal calibration to be performed in real-time as the probe is moved away from the phantom. We have evaluated the performance of our phantom by calibrating a probe at 8 cm and 15 cm depth. The precision of the calibrations are 0.7 mm and 1.2 mm, respectively. The point reconstruction accuracies of fiducial points provided by the same Z-phantom are slightly below 1.5 mm. The point reconstruction accuracies obtained by scanning the end of a wire tip are 2.5 mm and 3.0 mm. These results match the accuracies achieved in the literature. It takes approximately 2 min to set up the experiment, submerge the phantom in the water bath, locate the phantom in space with a pointer and capture six images of the planar membrane. After this, spatial calibration can be performed in less than a second. Temporal calibration can be completed in approximately 3 s.
منابع مشابه
Automated 3D Freehand Ultrasound Calibration with Real-Time Accuracy Control
3D ultrasound (US) is an emerging new imaging technology that appeals to more and more applications in intraoperative guidance of computer-assisted surgery. In a freehand US imaging system, US probe calibration is typically required to construct a 3D image of the patient's anatomy from a set of 2D US images. Most of the current calibration techniques concern primarily with the precision and acc...
متن کاملRobust and Automatic Calibration Method for 3D Freehand Ultrasound
This paper describes a new robust and fully automatic method for calibration of three-dimensional (3D) freehand ultrasound. 3D Freehand ultrasound consists in mounting a position sensor on a standard probe. The echographic B-scans can be localized in 3D, and can be compounded into a volume. However, especially for quantitative use, this process dramatically requires a calibration procedure that...
متن کاملImage-Based Method for In-Vivo Freehand Ultrasound Calibration
For freehand ultrasound systems, a calibration method is necessary to locate the position and orientation of a 2D B-mode ultrasound image plane with respect to a position sensor attached to the transducer. In addition, the acquisition time discrepancy between the position measurements and the image frames has the be computed. We developed a new method that adresses both of these problems, based...
متن کاملUltrasound Calibration Toolkit with a High-Adjustability Feature Based on User Requirements
3D freehand Ultrasound reconstruction is one of many choices to assemble 3D ultrasound volume from 2D ultrasound images with benefit in low-cost operations, conveniency and ease of usage which can be applied to intraoperative imaging. Ultrasound calibration is the procedure used to find the position and orientation of each acquired 2D ultrasound image in 3D space, hence is needed to be performe...
متن کاملA fully automatic calibration procedure for freehand 3D ultrasound
This paper describes a novel method for calibration of freehand three-dimensional (3D) ultrasound. A position sensor is mounted on a conventional ultrasound probe, thus the set of B-scans can be localized in 3D, and can be compounded into a volume. The calibration process aims at determining the transformation (translations, rotations, scaling) between the coordinates system of images and the c...
متن کاملFirst Year Progress Report Rapid, easy and reliable calibration for freehand 3D ultrasound
This paper presents improvements to the plane-based technique for calibrating freehand3D ultrasound systems. The improvements are designed to make it easier for inexperiencedusers to perform plane-based calibration and to know that they have got a reliable result.In particular, we enable the calibration to be performed using water at room temperaturewhile producing a result ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasound in medicine & biology
دوره 34 2 شماره
صفحات -
تاریخ انتشار 2008