Hot-film anemometer velocity measurements of arterial blood flow horses.

نویسندگان

  • R M Nerem
  • J A Rumberger
  • D R Gross
  • R L Hamlin
  • G L Geiger
چکیده

Blood velocity measurements were carried out using a constant-temperature hot-film anemometer system in both anesthetized and conscious horses. Catheter probes were used to measure velocity wave forms in conscious horses and L-shaped needle probes inserted by direct vessel puncture were used to measure the profiles in regions of the thoracic and abdominal aorta of anesthetized, open-chest horses. Both catheter and L-shaped probes were used for coronary velocity wave-form measurements. The flow conditions were characterized by peak Reynolds numbers of 200-10,000 and unsteadiness parameter of 2-30. These measurements indicate that in the thoracic aorta the flow at peak systole is largely inviscid with a thin-wall boundary layer; in the abdominal aorta the flow is more fully developed but skewed due to branching effects. Highly disturbed flows were observed in the thoracic aorta of both anesthetized and conscious horses, but not in the abdominal aortic region or in the coronary arteries. The results of this study indicate that the flow in the arterial system, although in many cases laminar and disturbance free, is extremely varied in character. It may be asymmetric and certainly is not representative of fully developed, Poiseuille flow.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hot-Film Anemometer Velocity Measurements of Arterial Blood Flow in Horses

Blood velocity measurements were carried out using a constant-temperature hot-film anemometer system in both anesthetized and conscious horses. Catheter probes were used to measure velocity wave forms in conscious horses and L-shaped needle probes inserted by direct vessel puncture were used to measure the profiles in regions of the thoracic and abdominal aorta of anesthetized, open-chest horse...

متن کامل

Measurements of disordered flows distal to subtotal vascular stenoses in the thoracic aortas of dogs.

Instantaneous blood velocity measurements employing a constant temperature hot film anemometer were obtained in the region distal to externally enforced, subtotal vascular stenoses in the descending thoracic aortas of anesthetized dogs. Our objectives were to determine alterations in velocity waveforms and energy spectra as the degree of stenosis was increased. We paid particular attention to d...

متن کامل

Velocity profiles in the main pulmonary artery of dogs and man, measured with a thin-film resistance anemometer.

Instantaneous velocity of pulmonary artery blood was measured using a thin-film resistance anemometer mounted on a hypodermic needle. Studies were performed, at thoracotomy, in five dogs and five patients. Instantaneous blood velocity was recorded at several sites across die transverse axis of the main pulmonary artery to determine the shape of the velocity profile. We found the velocity profil...

متن کامل

Application of heated-film velocity and shear probes to hemodynamic studies.

A constant-temperature heated-film anemometer system has been adapted for the detailed study of in-vivo aortic velocity fields. Two types of sensing probes were developed: a velocity probe and a velocity-gradient or fluid shear stress probe. These probes were evaluated for steady and pulsatile flow in rigid circular tubes using both a glycerin-water mixture and blood. Measurements using both de...

متن کامل

Parameterizable constant temperature anemometer: a new method for the analysis of velocity temperature coupling in turbulent heat transfer

A novel anemometer was designed and implemented for simultaneous measurement of velocity and temperature in air flows with a single hot wire probe. The principle of periodically varying the overheat ratio of the wire was selected and applied through a parameterizable electronic chain. The specific methods developed for the calibration procedure and the signal processing are explained. The accur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation research

دوره 34 2  شماره 

صفحات  -

تاریخ انتشار 1974