Intraoperative biometry for intraocular lens (IOL) power calculation at silicone oil removal.

نویسندگان

  • S M el-Baha
  • A el-Samadoni
  • H F Idris
  • K M Rashad
چکیده

PURPOSE Cataract development is common following retinal detachment surgery that necessitates silicone oil injection. Intraocular lens (IOL) power calculation in the presence of silicone oil is challenging for many reasons. The authors evaluated the accuracy of intraoperative biometry during cataract surgery in silicone-filled eyes. METHODS Twelve cases of cataract in eyes filled with silicone oil after retinal detachment surgery were included. Preoperatively, keratometric readings were documented. Intraoperative axial length was measured following removal of silicone oil using a sterile probe of the Nidek Echoscan US800 unit. IOL power calculation was computed using the SRK/T formula. This was followed by phacoemulsification and foldable lens implantation. Postoperative refraction allowed evaluation of the accuracy of intraoperative biometry. The predictability of three different formulas was also compared (Holladay, SRK/T, and SRK II). RESULTS Seven men and five women with a mean age of 50.2 years were included in the study. The mean postoperative spherical equivalent using the described technique was 6.77 +/- 0.43 diopters. SRK/T and Holladay formula had the best predictability for high axial length eyes, whereas the three studied formulas showed no significant differences in predictability in eyes with normal axial length. CONCLUSIONS Intraoperative biometry proved to have good predictability for the absolute postoperative refractive error in cataract surgery for eyes at the time of silicone oil removal. This predictability was accurate independent of axial length.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bilateral cataract after phakic posterior chamber top hat-style silicone intraocular lens.

BACKGROUND New strategies have been developed for surgical treatment of high myopia. Recently, implantation of minus power posterior chamber intraocular lenses (IOL) into phakic eyes has been introduced. METHODS We report a 37 year-old female patient who developed bilateral anterior subcapsular cataract 7 years after minus-power, top hat-style silicone posterior chamber IOL implantation in Ru...

متن کامل

Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation

PURPOSE To compare the outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery with monofocal IOL implantation. METHODS Preoperative data were obtained with the IOLMaster. Intraoperative aphakic measurements and IOL power calculations were obtained in some patients with the optiwave refract...

متن کامل

Visual Outcomes and Refractive Status after Combined Silicone Oil Removal/Cataract Surgery with Intraocular Lens Implantation

Purpose To evaluate refractive status and identify predictors of surgical success following a combined silicone oil removal/cataract surgery with intraocular lens (IOL) implantation procedure. Methods In this single-armed, retrospective study, we reviewed patients who underwent vitreoretinal surgery followed by a combined silicone oil removal/cataract surgery procedure between 2009 and 2013. ...

متن کامل

Limitations of Intraoperative Aphakic Refraction Technique for Intraocular Lens Power Calculation

Intraocular lens (IOL) power calculations are known to be difficult in eyes that have had corneal refractive surgery and several methods have been proposed to estimate IOL power. Among the methods not requiring preoperative data, the apahakic refraction technique has been successfully used to calculate IOL power in post-refractive cases and other conditions that cause unreliability in standard ...

متن کامل

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of ophthalmology

دوره 13 7  شماره 

صفحات  -

تاریخ انتشار 2003