Reverse-High Performance Liquid Chromatography Mechanism Explained by Polarization of Stationary Phase

نویسنده

  • Auréa Andrade-Eiroa
چکیده

Original results and conclusions on Reverse Phase High Performance Liquid Chromatography (RPLC) mechanism are here presented. So far, none of the theoretical approaches applied to the RPLC mechanism can explain the retention and elution mechanisms of most of the analytes by RPLC, especially neutral organic compounds. Our experiences allowed us to state that RPLC retention mechanism most likely occurs through polarization of stationary phase (usually dielectric surfaces) submerged into solvents with huge dielectric constant and high dipole moment (i.e. water and/or acetonitrile) at high pressures as those applied in RPLC systems. The surface polarized interacts with polarizable target analytes (i.e. naphthalene, pyrene or benzo(ghi)perylene) in such a way that the retention depends on the medium polarizability of the target compound. The higher is the medium polarizability of the compound retained the higher is its retention time. By using Polycyclic Aromatic Hydro-carbons (PAHs) and 6-nitrochrysene as probes, we found that although the dependence of retention times on pressure is not evident in most cases, the interaction between pressure and the mobile phase dipole moment is evidenced at the light of the constructed mathematical models. Two very different cases can be distinguished: 1. On one hand, when low dipole moment mobile phases are used, high pressure means big work developed by the system in such a way that high pressures inside the system reduce retention times compared to low pressures. 2. On the another one, when high dipole moment solvents are used as mobile phase, high pressure entails an outstanding increase of the retention times compared to low dipole moment mobile phases. This is most likely due to high pressures that entail closer alignment of mobile phase dipoles and lesser tilt of them, originating an outstanding electric field inside the analytical column. In addition to this, reduced retention times for dipole solutes (6-nitrochrysene, dipole molecule) compared to non-polar solutes (PAHs) were observed when pressure drops. This conclusions would allow to extend the model to basic/acid molecules at different pH. In this case, electrostatic repulsions among analyte molecules should be considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of 2-Amino Tetraphenyl Porphyrin as Stationary Phase in RP-HPLC of Amino Acids

The search for new stationary phases has been one of the predominant concerns in high performance liquid chromatography (HPLC) in order to achieve better resolutions, longer column lives, and reduce the time of analysis. A chromatographic packing for separation of underivatized amino acids (AAs) were prepared by dynamically coating 2-amino tetraphenyl prophyrin (atpp) on a C-18 reversed-pha...

متن کامل

Determination of chemical and radiochemical purity of [14C] clozapine by high performance liquid chromatography and liquid scintillation [Persian]

Introduction: The mechanism of action and metabolism of clozapine, a complex drug used in psychopharmacology, is not completely understood. The effects of this compound in human body are related to some interactions with serotonin and dopamine neurotransmitter receptors. To further elucidate the mechanism of action and to support ongoing drug metabolism studies, [14C] clozapine with suita...

متن کامل

Review High-performance liquid chromatographic enantioseparation of drugs containing multiple chiral centers on chiral stationary phases

In recent years there has been considerable interest in the synthesis and separation of enantiomers of organic compounds especially because of their importance in the biochemistry and pharmaceutical industry. High-performance liquid Chromatography is a very useful method for the direct separation of enantiomers. However, about 30−40 years ago, commercially available chiral stationary phases wer...

متن کامل

New Rp - Hplc Method Development and Validation for Analysis of Almotriptan

A simple, rapid and precise reverse phase high performance liquid chromatography method was developed for the analysis of Almotriptan. Chromatographic separation of Almotriptan was performed by using a kromosil C18 column (250 x 4.6mm, 5 μm) as stationary phase with a mobile phase comprising of 1% Triethyl amine : acetonitrile:methanol: 05:55:40 (v/v) at a flow rate of 1.0ml/min and UV detectio...

متن کامل

Comparison of the Retention of Aliphatic Hydrocarbons with Polar Groups in RP-HPLC Systems with Different Modifiers of the Binary Eluent

The retention of aliphatic hydrocarbons with polar groups has been compared in respect to the separation selectivity changes in reversed-phase high-performance liquid chromatography with C18 stationary phase type and binary water eluent composed of methanol, acetonitrile, or tetrahydrofuran as modifiers. The changes in separation selectivity when one modifier is replaced by another in the eluen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011