Evaluation of Hand-to-Hand Bioelectrical Impedance Analysis for Estimating Percent Body Fat in Young Adults

نویسندگان

  • AARON M. WEAVER
  • ASHLEY C. HILL
  • JOSEPH L. ANDREACCI
  • CURT B. DIXON
چکیده

Purposes were to (a) to examine the validity and precision of a hand-to-hand bioelectrical impedance analyzer (HBIA) and (b) to determine the effect of an acute sub-maximal aerobic exercise bout on HBIA percent body fat (%BF) measures. Forty-one young adults (21 women; 20 men) visited the laboratory for body composition assessment on two separate occasions. During the control session, %BF was assessed by HBIA twice, before and immediately after 30 min of rest, and once by air-displacement plethysmography (ADP), using the BOD POD, which was considered the criterion method for comparison. During the exercise session, HBIA %BF measurements were determined prior-to and immediately after 30 minutes of moderate-intensity treadmill exercise. HBIA significantly underestimated %BF in the total sample (mean difference (MD) = 1.4 ± 4.3%) and, when examined by gender, in the women (MD = 2.4 ± 4.1%). The standard errors of estimate (range 4.1-4.3%) also exceeded the recommended range for accuracy (<3.5%). Following exercise, there was minimal, but statistically significant reduction in HBIA-measured %BF pre- to post-exercise for the total sample (19.6 ± 6.0 vs. 19.3 ± 6.0%; p = 0.011). HBIA underestimated %BF when compared to ADP and the individual prediction error exceeded current recommendations when assessing young adults. In addition, performing sub-maximal aerobic exercise prior to the assessment decreased the %BF estimate. When one factors the exercise-induced alterations with the currently observed tendency for HBIA to underestimate %BF, it is apparent that exercise may further reduce the accuracy of this method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Bioelectrical Impedance and Skinfolds with Hydrodensitometry in the Assessment of Body Composition in Healthy Young Adults

Bioelectrical impedance analysis (BIA) is a widely used method for estimating body composition, yet issues concerning its validity persist in the literature. The purpose of this study was to validate percentage of body fat (BF) values estimated from BIA and skinfold (SF) with those obtained from hydrodensitometry (HD). Percent BF values measured via hand-to-hand BIA (BIAH), foot-to-foot BIA (BI...

متن کامل

Comparison of Muscle Mass, Total Body Water and Total Body Protein in Type II Diabetics with Healthy Matched Adults by Bioelectrical Impedance Analysis

Background: Bioelectrical impedance analysis (BIA) is a new and rapid technique to validate body composition. Several studies have used this technique to evaluate body compositions, such as muscle mass, in diabetic patients, but the results are very different. This may due the differences between diabetic patients and control group. Therefore, this study aimed to compare the muscle mass of diab...

متن کامل

Comparison of Total Fat, Percentage of Fat, Trunk Fat, Soft Lean and Mass Waist-Hip Ratio between Diabetic type II and Matched Non-Diabetic Iranians using Bioelectrical Impedance Analysis

Introduction: Research shows a relationship between diabetes (type II) and obesity. Bioelectrical Impedance Analysis (BIA) is a relatively new and approved method for the measurement of body composition. The aim of this study was to compare diabetic and non-diabetic adults on the basis of waist-hip ratio, total fat, percentage of fat, trunk fat, and soft lean mass. Methods: In this cross-sec...

متن کامل

Bioelectrical Impedance versus Body Mass Index for Predicting Body Composition Parameters in Sedentary Job Women

Objective: Nowadays the value of bioelectrical impedance analysis (BIA) in the estimation of body adiposity both on a clinical basis in the individual and epidemiologically in large populations is of great interest. The current study determine accuracy of BIA compared with body mass index (BMI) measurement for estimating body composition in a group of normal weight employee women with a sedenta...

متن کامل

Comparison of the predicting body fat equations during a maturation period in adolescent girls (12-16ys)

Validation of predicting fatness methods in the Iranian girls with respect to the maturity process could help to identify anthropometric risk factors. This study evaluate the accuracy of four body composition prediction equations in the teenager students in Hamadan city .Method: The anthropometry profile of 266 adolescent girls (12-16 ys) including ,weight (55.69±10.18 kg),body mass index (2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2009