Value of CMR in quantification of paravalvular aortic regurgitation after TAVI.
نویسندگان
چکیده
AIMS To assess the value of cardiac magnetic resonance (CMR) using phase-contrast velocity mapping for paravalvular aortic regurgitation (PAR) quantification. METHODS AND RESULTS All patients undergoing transcatheter aortic valve implantation (TAVI) in our centre between November 2012 and August 2013, without CMR-contraindication were included. PAR severity was assessed 5 days after TAVI using: transthoracic echocardiography (TTE) and CMR [regurgitant volume (RV), regurgitant fraction (RF)]. Aortic regurgitation (AR) index was obtained during TAVI. Thirty of 51 patients who underwent TAVI were included (COREVALVE, n = 10; or EDWARDS SAPIEN XT, n = 20). At TTE, PAR was mild in 22, moderate in 3, and severe in 5 patients. Reliable phase-contrast images were acquired at the sino-tubular junction for SAPIEN and at the tubular portion of the ascending aorta for COREVALVE. The reproducibility of CMR was high (coefficient of correlation = 0.99 for intra- and inter-operator variability). At CMR, RV, and RF were significantly (P < 0.0005) correlated with AR severity at TTE, with mean RF values at 9.2 ± 7.6% in mild, 20.3 ± 4.2% in moderate, and 46.8 ± 10.8% in severe PAR. A cut-off value of RF < 14% at CMR accurately discriminated mild from moderate/severe (sensitivity: 100%, specificity: 82%). The mean AR index was 29.4 ± 6 for mild and 13.8 ± 5 for moderate/severe PAR. Three patients had a RF > 14% and a low AR index <25 despite a mild PAR at TTE, suggesting an underestimation at TTE. CONCLUSION CMR is a reproducible, accurate, and reliable method to assess PAR severity. CMR may allow correcting an underestimation at TTE when AR index is doubtful.
منابع مشابه
Quantitative analysis of paravalvular leak of transcatheter aortic valves using cardiac MR
Background There is now extensive registry and clinical trial data demonstrating an increased incidence of paravalvular leak following transcatheter aortic valve implantation (TAVI) when compared with open aortic valve replacement (AVR). Despite recent improvements in both hardware and software, echocardiographic measurement of aortic regurgitation (AR) largely remains qualitative in nature. Ca...
متن کاملQuantitative analysis of post-TAVI aortic regurgitation with cardiovascular magnetic resonance and the relationship to transthoracic echocardiography
Background Transcatheter Aortic Valve Implantation (TAVI) is increasingly used to treat patients with severe aortic stenosis at high surgical risk. The severity of post-implantation valvular or paravalvular regurgitation has been shown to adversely affect patient outcome. The aim of the study was to assess the prevalence and severity of aortic regurgitation (AR) at 6 months post-TAVI using card...
متن کامل"Balloon withdrawal technique" to correct prosthesis malposition and treat paravalvular aortic regurgitation during TAVI.
Transcatheter aortic valve implantation (TAVI) is an emerging technology used to treat high-risk patients with severe aortic stenosis. During TAVI with the CoreValve ReValving System, a balloon is used for the reduction of paravalvular regurgitation. However, in this paper, we describe the "balloon withdrawal" technique through which the positioning of a second valve can be avoided in case of i...
متن کاملQuantification of paravalvular regurgitation after transcatheter aortic valve implantation: improved accuracy means better standardization.
Aortic stenosis (AS) is the most common valvular heart disease in western countries. Because of the ageing population, AS is being an increasing health problem with sizeable economic impact. AS is a gradually progressive disease, characterized by a long asymptomatic phase, lasting several decades, followed by a shorter symptomatic phase associated with severe narrowing of the orifice of the aor...
متن کاملIntraoperative 2D and 3D transoesophageal echocardiographic predictors of aortic regurgitation after transcatheter aortic valve implantation.
BACKGROUND Post-procedural aortic regurgitation (AR) has been described in a large number of patients receiving transcatheter aortic valve implantation (TAVI). OBJECTIVE The aim of this study was to examine the intraoperative 2-dimensional (2D) and 3-dimensional (3D) echocardiographic features of the aortic valve associated with significant post-procedural paravalvular AR. METHODS A total o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European heart journal cardiovascular Imaging
دوره 17 1 شماره
صفحات -
تاریخ انتشار 2016