Detection of Incipient Failures Using an H2-norm Criterion: Application to Electric Point Machines

نویسنده

  • Elena Zattoni
چکیده

The paper deals with condition monitoring of electric switch machines for railway points. The proposed detection system is based on off-line processing of armature current and voltage sampled as the machine operates a switch of railway tracks. The system, consisting of an algorithm tuned on a model of the machine as both the rails are driven towards their rest positions, allows detection of faults of an incremental nature, i.e. those connected to progressive increase of frictional loads (loss of lubrication, deterioration of slide chairs, increasing obstructions, etc). The algorithm realizes a finite impulse response system whose convolution profiles are designed on the basis of an H2-norm criterion which guarantees robustness, particularly with respect to electrical noise. Copyright c ©2005 IFAC

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Single and Dual Incipient Process Faults Using an Improved Artificial Neural Network

Changes in the physicochemical conditions of process unit, even under control, may lead to what are generically referred to as faults. The cognition of causes is very important, because the system can be diagnosed and fault tolerated. In this article, we discuss and propose an artificial neural network that can detect the incipient and gradual faults either individually or mutually. The mai...

متن کامل

Robust Control Problem as H 2 and H ∞ control problem applied to the robust controller design of Active Queue Management routers for Internet Protocol

During the last years, the Internet Application (Remote Flexible Control and Instrumentation, Telecontrol...) has retained the attention of Control researchers for modeling and studying the congestion control of TCP/IP (Transfer Control Protocol/Internet Protocol) networks. The controllers proposed in the literature such as RED (Random Early Detection) or PID (Proportional Integrate Derivative)...

متن کامل

Application of TPM indicators for analyzing work time of machines used in the pressure die casting

The article presents the application of total productive maintenance (TPM) to analyze the working time indicators of casting machines with particular emphasis on failures and unplanned downtime to reduce the proportion of emergency operation for preventive maintenance and diagnostics. The article presents that the influence of individual factors of complex machinery maintenance (TPM) is ...

متن کامل

Robust Model- Based Fault Detection and Isolation for V47/660kW Wind Turbine

In this paper, in order to increase the efficiency, to reduce the cost and to prevent the failures of wind turbines, which lead to an extensive break down, a robust fault diagnosis system is proposed for V47/660kW wind turbine operated in Manjil wind farm, Gilan province, Iran. According to the acquired data from Iran wind turbine industry, common faults of the wind turbine such as sensor fault...

متن کامل

A review on recent applications of brushless DC electric machines and their potential in energy saving

Electric motors are the largest consumer of world electric energy, consuming more than twice as much as lighting, the next largest consumer. Electric motors account for between 43 and 46% of all global electricity consumption approximately. They give rise to about 6 040 Mt of CO2 emissions. End‐users approximately spend USD 565 billion per year on electricity [1]. In recent years...