Reliability of latex agglutination tests for identification of Staphylococcus aureus resistant to oxacillin.

نویسندگان

  • A Punsalang
  • P C Migneault
  • F S Nolte
چکیده

Commercial latex agglutination tests (LATs) for the simultaneous detection of clumping factor and protein A are gaining increased acceptance as a means of identifying Staphylococcus aureus. We evaluated two LATs (Accu-Staph; Carr-Scarborough, Decatur, Ga.; Staphaurex; Wellcome, Dartford, England) with particular emphasis on their ability to correctly identify oxacillin-resistant S. aureus. We tested 59 oxacillin-resistant S. aureus, 136 oxacillin-susceptible S. aureus, and 92 coagulase-negative staphylococcal strains with the two LATs and with thermonuclease, slide clumping factor, tube coagulase, and protein A hemagglutination tests. Clumping factor and protein A were present in 96.9 and 82.1% of our S. aureus strains, respectively. Accu-Staph correctly identified 92.8% and Staphaurex correctly identified 91.3% of S. aureus strains. No significant difference in LAT positivity rates, presence of clumping factor, or presence of protein A was found between oxacillin-resistant and -susceptible S. aureus. Overall, there were 31 false-negative LATs for 20 S. aureus strains, 14 with Accu-Staph and 17 with Staphaurex. Ninety-five percent of these strains possessed either clumping factor or protein A or both when these factors were determined independently. There were five false-positive LATs for four strains of coagulase-negative staphylococci (three Staphylococcus epidermidis and one Staphylococcus warneri), four with Accu-Staph and one with Staphaurex. Clumping factor was present in one S. warneri strain. Thus, the specificities of Accu-Staph, Staphaurex, and the clumping factor test were 95.6, 98.9, and 98.9%, respectively. Our results indicated that LATs identify oxacillin-resistant and -susceptible S. aureus equally well; however, they offer no greater sensitivity or specificity than the clumping factor test for identification of S. aureus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of penicillin binding protein 2a latex agglutination assay for identification of methicillin-resistant Staphylococcus aureus directly from blood cultures.

The penicillin binding protein 2a (PBP2a) latex agglutination test using a blood culture pellet was compared to the oxacillin screen agar method using isolated colonies. For blood cultures positive for Staphylococcus aureus (n = 70), the direct PBP2a test was 18% sensitive and 100% specific. The PBP2a test shows poor sensitivity when used directly with positive blood cultures.

متن کامل

Failure of rapid agglutination methods to detect oxacillin-resistant Staphylococcus aureus.

Although a latex agglutination test (StaphAurex) and a hemagglutination test (Staphyloslide) correctly identified all strains of Staphylococcus aureus that were susceptible or had intermediate susceptibility to oxacillin, 17 of 73 (23%) and 18 of 73 (25%) strains of oxacillin-resistant S. aureus were not identified by StaphAurex and Staphyloslide, respectively. All strains not detected were res...

متن کامل

Evaluation of the Mastalex latex agglutination test for methicillin resistance in Staphylococcus aureus grown on different screening media.

The Mastalex MRSA latex agglutination method was evaluated with 52 methicillin-resistant and 27 methicillin-susceptible strains of Staphylococcus aureus grown on various media. All tests were correct with colonies grown on blood agar with or without oxacillin 2 mg/L. Tests on colonies grown on mannitol salt agar were less reliable, although addition of oxacillin 2 mg/L improved performance. One...

متن کامل

Comparison of phenotypic versus genotypic methods in the detection of methicillin resistance in Staphylococcus aureus.

BACKGROUND & OBJECTIVE Conventional methods to detect methicillin resistance in Staphylococcus aureus are inadequate as expression of resistance is subject to environmental and conditional expression of PBP2a antigen. The objective of the present study was to determine methicillin resistance in S. aureus by conventional susceptibility (oxacillin disc diffusion and oxacillin MIC) and molecular m...

متن کامل

Evaluation of three rapid methods for detection of methicillin resistance in Staphylococcus aureus.

The probe-based Velogene Rapid MRSA Identification Assay (ID Biomedical Corp., Vancouver, British Columbia, Canada) and the latex agglutination MRSA-Screen (Denka Seiken Co., Tokyo, Japan) were evaluated for their ability to identify methicillin-resistant Staphylococcus aureus (MRSA) and to distinguish strains of MRSA from borderline oxacillin-resistant S. aureus (BORSA; mecA-negative, oxacilli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 1986