چکیده
Abstract. We use an analytic approach to study the susceptibility of the P Low Frequency Instrument radiometers to various systematic effects. We examine the effects of fluctuations in amplifier gain, in amplifier noise temperature and in the reference load temperature. We also study the effect of imperfect gain modulation, non-ideal matching of radiometer parameters, imperfect isolation in the two legs of the radiometer and back-end 1/ f noise. We find that with proper gain modulation 1/ f gain fluctuations are suppressed, leaving fluctuations in amplifier noise temperature as the main source of 1/ f noise. We estimate that with a gain modulation factor within ±1% of its ideal value the overall 1/ f knee frequency will be relatively small (<0.1 Hz).
منابع مشابه
Planck pre-launch status: Calibration of the Low Frequency Instrument flight model radiometers
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called radiometer chain assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cry...
متن کاملPlanck LFI : Comparison Between Galaxy Straylight Contamination and other Systematic Effects
The straylight contamination due to the Galactic emission (GSC, Galaxy Straylight Contamination) entering at large angles from the antenna centre direction may be one of the most critical sources of systematic effects in observations of the cosmic microwave background (CMB) anisotropies by future satellite missions like Planck and MAP. For the Low Frequency Instrument (LFI), this effect is expe...
متن کاملThe Planck-LFI instrument: analysis of the 1/f noise and implications for the scanning strategy
We study the impact of 1/f noise on the Planck Low Frequency Instrument (LFI) observations (Mandolesi et al. 1998) and describe a simple method for removing striping effects from the maps for a number of different scanning strategies. A configuration with an angle between telescope optical axis and spin-axis just less than 90 (namely ≃ 85) shows good destriping efficiency for all receivers in t...
متن کاملPlanck pre-launch status: Expected LFI polarisation capability
We present a system-level description of the Low Frequency Instrument (LFI) considered as a differencing polarimeter, and evaluate its expected performance. The LFI is one of the two instruments on board the ESA Planck mission to study the cosmic microwave background. It consists of a set of 22 radiometers sensitive to linear polarisation, arranged in orthogonally-oriented pairs connected to 11...
متن کاملPlanck 2013 results . V . LFI calibration
We discuss the methods employed to photometrically calibrate the data acquired by the Low Frequency Instrument on Planck. Our calibration is based on the Solar Dipole, caused by motion of the Solar System with respect to the CMB rest frame, which provides a signal of a few mK with the same spectrum as the CMB anisotrophies and is visible throughout the mission. In this data release we rely on t...
متن کامل