The Same Angiographic Factors Predict Venous and Arterial Graft Patency
نویسندگان
چکیده
To evaluate the value of angiographic factors in predicting failure of both venous and arterial coronary artery bypass graft. We retrieved from our angiographic database 148 patients who underwent venous and/or arterial CABG and for whom a control coronary angiography at more than 1 month after surgery was available. Pre-CABG and follow-up angiographies were analyzed in order to evaluate diameter stenosis (DS,%), stenosis length (mm), Bogaty score (extent index), Sullivan score, and Gensini score for the extent of coronary artery disease, and Jeopardy Duke score for the extent of myocardial area supplied by an artery. Thirty-nine patients (26%) experienced graft failure at follow-up (mean follow-up 11.3 ± 4.6 months). Patients with venous graft failure [26 (20%)] had significantly smaller DS (P = 0.013), shorter stenosis length (P = 0.01), and lower extent index (P = 0.015), Sullivan score (P = 0.013), Gensini score (P = 0.04) as compared with those without venous graft failure. Patients with arterial graft failure [13 (11%)] had significantly lower DS (P = 0.008), shorter stenosis length (P = 0.001), and lower extent index (P = 0.03) and Sullivan score (P = 0.023) as compared with those without arterial graft failure. Venous and arterial graft failure are associated with less severe stenosis and less extensive atherosclerosis of the grafted vessel.
منابع مشابه
Surgical infrainguinal revascularization for peripheral arterial disease: factors affecting patency rate
Background: Peripheral arterial disease is a source of morbidity and mortality. Surgical vascular reconstruction is a treatment option but probability of failure and complications are important concerns. In this study, we evaluated outcome of surgical infrainguinal reconstruction and factors affecting graft patency for a period of one year. Methods: In this cohort study, 85 consecutive patie...
متن کاملارزیابی و مقایسه عوارض وتمامیت فیستول شریانی- وریدی باگرافت گورتکس 6 و 8 میلیمتری در اندام فوقانی و مقایسه آنها با گرافت گورتکس 8 میلیمتری اندام تحتانی در یک سال اول پس از عمل
Background & Aims: This study was done in hem dialysis patients who referred to Imam Khomeini hospital of Urmia for insertion of arterial -venous fistula with Gore-tex, in whom there was not possibility of natural fistula. Objectives were assessment and comparison of complications and patency of arterial-venous fistulas was done with 6 and 8 mm Gore-tex graft in the upper limb and comparison of...
متن کاملArterial versus venous bypass grafts in patients with in-stent restenosis.
BACKGROUND In patients who develop in-stent restenosis, successful revascularization can be difficult to achieve using percutaneous methods. This study was designed to verify the surgical results in this setting and to evaluate the potential beneficial role of arterial bypass conduits. METHODS AND RESULTS Sixty consecutive coronary artery bypass patients with previous in-stent restenosis and ...
متن کاملThe Effect of Antiplatelet Drugs on the Patency Rate of Arterio-venous Fistulae in Hemodialysis Patients
Although arterialovenous fistulae (AVF) is considered to be vital for chronic kidney disease (CKD) patients, but they may cause complications and problems. For instance they may fail soon after their creation. The most important cause of failure in these cases is intrafistula thrombus formation. Whereas anti-platelet drugs are not routinely used after fistulae creation, we conducted this stud...
متن کاملThe Effect of Antiplatelet Drugs on the Patency Rate of Arterio-venous Fistulae in Hemodialysis Patients
Although arterialovenous fistulae (AVF) is considered to be vital for chronic kidney disease (CKD) patients, but they may cause complications and problems. For instance they may fail soon after their creation. The most important cause of failure in these cases is intrafistula thrombus formation. Whereas anti-platelet drugs are not routinely used after fistulae creation, we conducted this stud...
متن کامل