[Minimum effective concentration of bupivacaine for axillary brachial plexus block guided by ultrasound].
نویسندگان
چکیده
INTRODUCTION The use of ultrasound in regional anesthesia allows reducing the dose of local anesthetic used for peripheral nerve block. The present study was performed to determine the minimum effective concentration (MEC90) of bupivacaine for axillary brachial plexus block (ABPB). METHODS Patients undergoing hand surgery were recruited. To estimate the MEC90, a sequential up-down biased coin method of allocation was used. The bupivacaine dose was 5mL for each nerve (radial, ulnar, median, and musculocutaneous). The initial concentration was 0.35%. This concentration was changed by 0.05% depending on the previous block: a blockade failure resulted in increased concentration for the next patient; in case of success, the next patient could receive or reduction (0.1 probability) or the same concentration (0.9 probability). Surgical anesthesia was defined as driving force ≤ 2 according to the modified Bromage scale, lack of thermal sensitivity and response to pinprick. Postoperative analgesia was assessed in the recovery room with numeric pain scale and the amount of drugs used within 4hours after the blockade. RESULTS MEC90 was 0.241% [R2: 0.978, confidence interval: 0.20%-0.34%]. No successful block patient reported pain after 4hours. CONCLUSION This study demonstrated that ultrasound guided ABPB can be performed with the use of low concentration of local anesthetics, increasing the safety of the procedure. Further studies should be conducted to assess blockade duration at low concentrations.
منابع مشابه
Estimation of the minimum effective volume of 0.5% bupivacaine for ultrasound-guided axillary brachial plexus block.
BACKGROUND AND OBJECTIVE The use of ultrasound for needle correct placement and local anesthetic spread monitoring helped to reduce the volume of local anesthetic required for peripheral nerve blocks. There are few studies of the minimum effective volume of local anesthetic for axillary brachial plexus block. The aim of this study was to determine the minimum effective volume (VE90) of 0.5% bup...
متن کاملMinimum effective volume of 0.5% bupivacaine with epinephrine in ultrasound-guided interscalene brachial plexus block.
BACKGROUND The use of ultrasound (US) in regional anaesthesia enables a reduction in the local anaesthetic volume. The present study aimed to determine the minimum effective volume (MEV(90)) of 0.5% bupivacaine with epinephrine for interscalene brachial plexus block (ISBPB). METHODS The volume of the anaesthetic was determined using a step-up/step-down method and was based on the outcome of t...
متن کاملOnset Time of 2% Lidocaine and 0.5% Bupivacaine Mixture versus 0.5% Bupivacaine Alone using Ultrasound and Double Nerve Stimulation for Infraclavicular Brachial Plexus Anesthesia in ESRD Patients Undergoing Arteriovenous Fistula Creation.
OBJECTIVE To reduce the onset of 0.5% bupivacaine by adding 2% lidocaine with 0.5% bupivacaine for ultrasound-guided and double stimulation technique at musculocutaneous and radial nerve for infraclavicular brachial plexus block. DESIGN Prospective randomized double-blinded, controlled trial study. MATERIAL AND METHOD 90 patients undergoing creation of arteriovenous fistula under ultrasound...
متن کاملUltrasound Guided Infraclavicular Block for Pain Control After Upper Extremity Surgery
Background: Opioids added to local anesthetics for peripheral nerve blocks may intensify analgesia and prolong analgesic and sensorial block duration. These agents may also cause potentiation and prolongation of motor block. Objective: This study compared the postoperative effects of 30 mL of 0.25% bupivacaine +50 mcg fentanyl and 30 mL of 0.25% bupivaca...
متن کاملUltrasound guided axillary brachial plexus block.
The axillary brachial plexus block is the most widely performed upper limb block. It is relatively simple to perform and one of the safest approaches to brachial plexus block. With the advent of ultrasound technology, there is a marked improvement in the success rate of the axillary block. This review will focus on the technique of ultrasound guided axillary brachial plexus block.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian journal of anesthesiology
دوره 65 3 شماره
صفحات -
تاریخ انتشار 2015