Delamination of abluminal polymer of biolimus-eluting stent.
نویسندگان
چکیده
Manuscript received August 10, 2011; accepted September 3, 2011. Corporation, Tokyo, Japan) with abluminal biodegradable polymer in the mid-RCA was attempted. It passed through the everolimus-eluting stent in the proximal RCA without difficulty. However, it would not advance to the target lesion in the mid-RCA (Fig. 1C). Additional balloon inflation was performed. A 12-mm Driver Sprint stent (Medtronic, Minneapolis, Minnesota) was then deployed in the
منابع مشابه
Biolimus-eluting biodegradable polymer-coated stent versus durable polymer-coated sirolimus-eluting stent in unselected patients receiving percutaneous coronary intervention (SORT OUT V): a randomised non-inferiority trial.
BACKGROUND Third-generation biodegradable polymer drug-eluting stents might reduce the risk of stent thrombosis compared with first-generation permanent polymer drug-eluting stents. We aimed to further investigate the effects of a biodegradable polymer biolimus-eluting stent compared with a durable polymer-coated sirolimus-eluting stent in a population-based setting. METHODS This randomised, ...
متن کاملAssessment of stent strut endothelialization in iliac arteries of rabbits.
BACKGROUND Fast post-implantation stent endothelialization is desirable for theoretically reducing the possibility of stent thrombosis. OBJECTIVE To evaluate the extent of sirolimus-eluting stent strut endothelialization (delivered from the luminal and abluminal aspects or abluminal aspect only) in the iliac arteries of rabbits. METHODS The iliac arteries of 10 rabbits were implanted with f...
متن کاملThe twelve-month outcome of biolimus eluting stent with biodegradable polymer compared with an everolimus eluting stent with durable polymer.
INTRODUCTION Drug-eluting stents (DES) have significantly decreased the need for repeat coronary revascularization but concerns remain regarding the safety of first and second generation DES. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with an everolimus-eluting stent (with durable polymer) one. METHODS We performed a randomized trial to compar...
متن کاملEffect of biolimus-eluting stents with biodegradable polymer vs bare-metal stents on cardiovascular events among patients with acute myocardial infarction: the COMFORTABLE AMI randomized trial.
CONTEXT The efficacy and safety of drug-eluting stents compared with bare-metal stents remains controversial in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI). OBJECTIVE To compare stents eluting biolimus from a biodegradable polymer with bare-metal stents in primary PCI. DESIGN, SETTING, AND PATIENTS A prospectiv...
متن کاملPolymer-free biolimus a9-coated stent demonstrates more sustained intimal inhibition, improved healing, and reduced inflammation compared with a polymer-coated sirolimus-eluting cypher stent in a porcine model.
BACKGROUND Drug-eluting stents effectively reduce restenosis but may increase late thrombosis and delayed restenosis. Persistent polymer, the drug, or a combination of both could be responsible. Local delivery of Biolimus A9, a rapamycin derivative, from a polymer-free BioFreedom stent (Biosensors International) may prevent these complications. METHODS AND RESULTS We compared high-dose (HD) (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JACC. Cardiovascular interventions
دوره 5 3 شماره
صفحات -
تاریخ انتشار 2012