The Multiple Silicone Tube Device, “Tubes within a Tube,” for Multiplication in Nerve Reconstruction

نویسندگان

  • Fredrik Johansson
  • Lars B Dahlin
چکیده

Multiple nerve branches were created during the regeneration procedure after a nerve injury and such multiple branches are suggested to be used to control, for example, prosthesis with many degrees of freedom. Transected rat sciatic nerve stumps were inserted into a nine mm long silicone tube, which contained four, five mm long, smaller tubes, thus leaving a five mm gap for regenerating nerve fibers. Six weeks later, several new nerve structures were formed not only in the four smaller tubes, but also in the spaces in-between. The 7-9 new continuous nerve structures, which were isolated as individual free nerves after removal of the tubes, were delineated by a perineurium and contained both myelinated and unmyelinated nerve fibers as well as blood vessels. Stimulation of the proximal nerve elicited contractions in distal muscles. Thin metal electrodes, inserted initially into the smaller tubes in some experiments, became embedded in the new nerve structures and when stimulated contractions of the distal muscles were observed. The "tubes within a tube" technique, creating multiple new nerves from a single "mother" nerve, can be used to record multiple signals for prosthetic device control or as sources for supply of multiple denervated targets.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bridging Small-Gap Peripheral Nerve Defect Using Silicone Rubber Chamber in the Rat Sciatic Nerve Transection Model

  Despite promising results observed using silicone rubber chamber, no previous comprehensive work was performed on behavior of the conduit. Present study aimed at further functional, histomorphometrical and immunohistochemical assessment of nerve regeneration in the same animal along a 10-mm rat sciatic nerve gap. Fifty- four male Wistar rats were divided into three experimental groups (n = 1...

متن کامل

Structural and functional improvement of snipped sciatic nerve after allograft injection of Schwann cells into fibrin scaffold

Background and Aim: Peripheral nerve injuries are among the most common types of injuries of the nervous system and are regarded as the main cause of disability. These injuries can lead to disorders in muscles movement and normal sense, and also painful neuropathy. Tissue engineering and stem cells therapy are among the treatment methods for these disorders. In this study we assessed sciatic ne...

متن کامل

Two-Stage Nerve Graft in Severe Scar: A Time-Course Study in a Rat Model

excessive scarring; paralleling the process in tendon reconstruction of the hand. Inspired by the advantages of the two-stage technique in tendon grafting and with encouraging preliminary results, we aimed to investigate the two-stage nerve grafting technique as an alternative method of secondary nerve repair. Methods:  Thirty female rats (~200 g) were randomly distributed into two groups (n=15...

متن کامل

Effect of Local Administration of Brain Derived Neurotrophic Factor with Silicone Conduit on Peripheral Nerve Regeneration: a Rat Sciatic Nerve Transection Model

Objective- The objective was to assess local effect of brain derived neurotrophic factor (BDNF) on functional recovery of peripheral nerve in rat sciatic nerve transection model. Design- Experimental study. Animals- Sixty male healthy white Wistar rats Procedures- The animalswere randomized into four experimental groups of 15 animals each: In sham-operated group (SHAM), sciatic nerve was exp...

متن کامل

Ultrastructural and Morphometric Analysis of Peripheral Nerve Regeneration Within Silicone Tubes

203 Abstract: Semi-thin and thin sections were used to observe the morphogenesis of peripheral nerves regenerating in silicone tubes. The progress of peripheral nerve regeneration across a 10 mm gap within the silicone tubes was examined after 3, 6 and 9 months. The left sciatic nerves of rats were transected. The proximal and distal nerve stumps were inserted into a silicone tube, in which the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014