Impact of acoustic window on accuracy of longitudinal global strain: a comparison study to cardiac magnetic resonance.

نویسندگان

  • Laurent Macron
  • Olivier Lairez
  • Julien Nahum
  • Mathieu Berry
  • Leslie Deal
  • Jean-François Deux
  • Alexandre Bensaid
  • Jean-Luc Dubois Randé
  • Pascal Gueret
  • Pascal Lim
چکیده

AIMS To evaluate the impact of acoustic window on the feasibility and accuracy of longitudinal global strain (global-ε) by speckle tracking for assessing left ventricular (LV) systolic function. METHODS AND RESULTS The study included 70 patients (57 ± 17 years, 64% men), 28 selected patients with a suboptimal image quality (IQ) defined by three or more segments (4 ± 3 segments/patient) with wall motion score not analysable visually and 42 patients with an optimal two-dimensional (2D) echocardiography IQ. Left ventricular ejection fraction (LVEF) by Simpson's biplane method (2D-EF), global-ε by speckle tracking, and peak systolic mitral annulus velocity [systolic tissue Doppler imaging (S-TDI)] were compared with LVEF by cardiac magnetic resonance (EF-CMR; 45 ± 18%, range 9-76%). Speckle-tracking analysis was feasible in all segments with an optimal acoustic window and in 85% (103/121) of segments poorly visualized. Global-ε similarly correlated with LVEF by CMR in patients with and without optimal IQ (r = 0.81 vs. 0.82 for good vs. poor IQ). In contrast, 2D-EF (r = 0.76) and S-TDI (r = 0.64) less correlated with LVEF by CMR in patients with a suboptimal IQ. Importantly, IQ only impacted on 2D-EF inter-observer reproducibility (9 ± 5 vs. 24 ± 22% for good vs. poor IQ) but not on global-ε reproducibility (9 ± 1 vs. 8 ± 7% for good vs. poor IQ). CONCLUSION In patients with a limited acoustic window, longitudinal strain by speckle tracking remains accurate and reproducible for assessing global and regional LV systolic function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DNA Damages on Blood Cells After Cardiac Magnetic Resonance Imaging

Introduction: Along with the increased use of cardiac imaging at clinics there is increased attention to the potential risks related to the methods used like magnetic resonance (MR) and it cannot be ruled out that MR can alter DNA structure. The aim of this review is to assess the impact of routine cardiac magnetic resonance (CMR) scanning on DNA damages in human T lymphocytes....

متن کامل

Evaluation of Global Longitudinal Strain Pattern (GLS) and Echocardiographic Parameters in the Sleeve Gastrectomy Patients Before and After Surgery

Background and Objective: Obesity is one of the problems associated with cardiovascular complications. Patients' heart function improves after sleeve gastrectomy. Global Longitudinal Strain (GLS) is one of the methods used to monitor heart function before and after sleeve gastrectomy.  In this study, we evaluated the echocardiographic parameters pre and post sleeve gastrectomy. Materials and M...

متن کامل

Relationship between Late Gadolinium Enhancement Extent in Cardiac Magnetic Resonance Imaging and Severity of Coronary Artery Disease in Old Myocardial Infarction

Purpose: To assess the relationship between the severity of coronary arteries involvement and the extent and pattern of myocardial scars in Cardiac Magnetic Resonance of patients with history of remote myocardial infarction. Materials and Methods: The Cardiac Magnetic Resonance images of sixty patients with history of remote ST segment or non-ST segment elevation myocardial infarction were ...

متن کامل

Quantification of biventricular myocardial function using cardiac magnetic resonance feature tracking, endocardial border delineation and echocardiographic speckle tracking in patients with repaired tetralogy of fallot and healthy controls

BACKGROUND Parameters of myocardial deformation have been suggested to be superior to conventional measures of ventricular function in patients with tetralogy of Fallot (ToF), but have required non-routine, tagged cardiovascular magnetic resonance (CMR) techniques. We assessed biventricular myocardial function using CMR cine-based feature tracking (FT) and compared it to speckle tracking echoca...

متن کامل

Comparison of GLS via echocardiography and tissue tracking by Cardiac Magnetic Resonance imaging

Background Global longitudinal strain (GLS), has shown utility in detecting early subclinical LV dysfunction and has demonstrated significant efficacy in evaluating patients for chemotherapy cardiotoxicity. However, echocardiography is often reliant on operator experience and adequate quality windows for assessment. CMR is not subject to limitations of poor image quality due to its superior end...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology

دوره 12 5  شماره 

صفحات  -

تاریخ انتشار 2011