Comparison of deformation and torque expression of the orthos and orthos Ti bracket systems.

نویسندگان

  • Garrett W Melenka
  • Ryan A Lacoursiere
  • Jason P Carey
  • David S Nobes
  • Giseon Heo
  • Paul W Major
چکیده

Orthodontic torque expression is the result of axial rotation of rectangular archwires within a rectangular bracket slot. This study investigates the effect of bracket material on torque expression. Torque exerted by a rotating archwire on each bracket will be measured as well as the relative deformation of each bracket slot. A total of 60 tests were performed where archwires were rotated within a bracket slot to produce torque within a bracket. Thirty Ormco Orthos Ti and 30 Orthos SS were compared to investigate the effect of torque on bracket material. Each bracket was mounted on a six-axis load cell that measured forces and moments in all directions. The archwire was rotated from an initial angle of 0 degree in 3 degrees increments to maximum angle of 51 degrees and then returned to the initial position. An overhead camera took images at each 3 degrees increment. The bracket images were post-processed using a digital image correlation technique to measure the relative deformation of each bracket slot. The maximum torque expressed at 51 degrees was 99.8 Nmm and 93.0 Nmm for Orthos Ti and Orthos SS, respectively. Total plastic deformation measured at 0 degrees post-torquing of the Orthos SS was 0.038 mm compared to 0.013 mm for Orthos Ti. The Orthos Ti brackets plastically deformed less than the Orthos SS brackets after torquing. The Orthos SS bracket plastic deformation was 2.8 times greater than that of Orthos Ti brackets. The Orthos Ti brackets expressed more torque than the stainless steel brackets but exhibited substantial variation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the effectiveness of indirect bonding of orthodontic attachments with RMGIC Resin Modified Glass-Ionomer Cement

This article reports our study, carried out as a CECSMO assignment, assessing the effectiveness of resin modified glass ionomer cement as a bonding agent on enamel over a two year period and a consideration of the relative influence of two brands of attachments, Orthos and Damon. In our study group we had an overall rate of bonding rupture of 11.6%. 17% of direct and 33% of the indirect bonding...

متن کامل

Shear bond strength comparison between two orthodontic adhesives and self-ligating and conventional brackets.

OBJECTIVE To evaluate and compare the shear bond strengths of two adhesives using two types of brackets: a conventional and a self-ligating bracket system. MATERIALS AND METHODS Sixty extracted human premolars were collected. The premolars were randomly divided into three groups of 20 teeth. All three groups were direct bonded. Groups 1 and 2 used light-cured adhesive and primer (Transbond XT...

متن کامل

Comparison of slot deformation in stainless steel and ceramic brackets during torque - A finite element analysis

Introduction: Torque in orthodontics is vital in final positioning of the teeth during fixed appliance therapy. Torqueing of archwires is a significant factor in transferring the applied forces to the bracket which might cause deformation of the slot. Any deformation in the bracket slot can vary the torque prescription and thus can affect the tooth position. Aim: To evaluate and compare the def...

متن کامل

Measurement of Orthodontic Bracket Tie Wing Elastic and Plastic Deformation by Arch Wire Torque Expression Utilizing an Optical Image Correlation Technique

Orthodontic lingual root movement (torque) is an important aspect of treatment biomechanics and is typically achieved by torsion of a rectangular wire within the orthodontic bracket slot which introduces a force couple. The magnitude of the force moment achieved by wire torsion may be influenced by deformation of the orthodontic bracket. A device utilizing an optical image correlation technique...

متن کامل

An investigation into the mechanical characteristics of select self-ligated brackets at a series of clinically relevant maximum torquing angles: loading and unloading curves and bracket deformation.

Edgewise orthodontic treatment utilizes a force couple in order to achieve labial-lingual tooth angulation. Two self-ligating brackets (Damon Q and Speed) were examined across a range of clinically relevant torques in order to assess the loading and unloading curves and bracket deformation. A previously developed torquing and load measurement system was utilized to rotate a 0.199 × 0.25 in stai...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 36 4  شماره 

صفحات  -

تاریخ انتشار 2014