Functional Visual Acuity of Early Presbyopia
نویسندگان
چکیده
PURPOSE To evaluate visual function in patients with early presbyopia using the functional visual acuity (FVA) test. METHODS This study included 27 eyes of 27 healthy older volunteers (mean age, 44.1 ± 2.6 years) and 14 eyes of 14 healthy young volunteers (mean age, 28.4±4.8 years). The distance-corrected visual acuity (DCVA), distance-corrected near VA (DCNVA), subjective amplitude of accommodation (AA), and distance and near pupillary diameters were measured. The distance FVA and distance-corrected near FVA (DCNFVA) were measured using the FVA Measurement System. The standard Schirmer test and standard tear break-up time measurement also were performed. RESULTS The logarithm of the minimum angle of resolution (logMAR) DCVA was better than 0 in all subjects. The percentages of subjects with logMAR DCNVA below 0 was significantly lower in the presbyopia group than in the young group. The DCNFVA in the presbyopia group was significantly (P < 0.001) poorer than the DCNVA in that group. Significant linear negative correlations were seen between the DCNVA and AA (r = -0.507, P < 0.001) and the DCNFVA and AA (r = -0.681, P < 0.001) in the older subjects. Stepwise regression analysis showed that only the AA was a significant factor predictive of the DCNFVA in the presbyopia group. Tear function parameters were not adopted in the regression model. CONCLUSIONS Measurement of the DCNFVA can detect decreased AA in early presbyopia better than measurement of the conventional near VA. The DCNFVA is a good index for early presbyopia.
منابع مشابه
Early outcomes of INTRACOR femtosecond laser treatment for presbyopia.
PURPOSE To investigate early functional outcomes of the INTRACOR femtosecond laser-based intrastromal procedure to treat presbyopia. METHODS Twenty-five eyes of 25 presbyopic patients were enrolled in this prospective, ethics committee-approved study. Following detailed preoperative examination, the INTRACOR procedure was performed using the TECHNOLAS femtosecond laser (Technolas Perfect Visi...
متن کاملComputer-based primary visual cortex training for treatment of low myopia and early presbyopia.
PURPOSE The NeuroVision technology is a noninvasive, patient-specific, perceptual learning program based on visual stimulation and facilitation of neural connections at the cortical level, involving a computerized visual training regimen using Gabor patches, to improve contrast sensitivity and visual acuity. The efficacy of NeuroVision in enhancing uncorrected visual acuity (UCVA) and unaided c...
متن کاملCorneal compensation of presbyopia: PresbyLASIK: an updated review
ABSTRACT The main purpose of this review is to compare and analyze the results of the main PresbyLASIK approaches; central and peripheral. SUMMARY A comprehensive research was conducted in PUBMED using keywords like "presbyopia correction", "PresbyLASIK", "Corneal multifocality", "Laser blended vision". We reviewed the PresbyLASIK technique, uncorrected distance visual acuity (UDVA), correcte...
متن کاملIntrastromal femtosecond laser presbyopia correction: 1-year results of a multicenter study.
PURPOSE To investigate functional outcomes of the INTRACOR femtosecond laser-based intrastromal procedure to treat presbyopia. METHODS Sixty-three eyes from 63 presbyopic patients (median age: 54 years) with mild hyperopia were enrolled in this prospective, ethics committee-approved, multi-center, nonrandomized clinical trial. The INTRACOR procedure was performed using the Technolas femtoseco...
متن کاملVisual and Refractive Outcomes of a Toric Presbyopia-Correcting Intraocular Lens
Purpose. To evaluate outcomes in astigmatic patients implanted with the Trulign (Bausch + Lomb) toric presbyopia-correcting intraocular lens (IOL) during cataract surgery in a clinical practice setting. Methods. Retrospective study in 40 eyes (31 patients) that underwent cataract extraction and IOL implantation in a procedure using intraoperative wavefront aberrometry guidance (ORA system). End...
متن کامل