Rotary ultrasonic bone drilling: Improved pullout strength and reduced damage.

نویسندگان

  • Vishal Gupta
  • Pulak M Pandey
  • Vadim V Silberschmidt
چکیده

Bone drilling is one of the most common operations used to repair fractured parts of bones. During a bone drilling process, microcracks are generated on the inner surface of the drilled holes that can detrimentally affect osteosynthesis and healing. This study focuses on the investigation of microcracks and pullout strength of cortical-bone screws in drilled holes. It compares conventional surgical bone drilling (CSBD) with rotary ultrasonic bone drilling (RUBD), a novel approach employing ultrasonic vibration with a diamond-coated hollow tool. Both techniques were used to drill holes in porcine bones in an in-vitro study. Scanning electron microscopy was used to observe microcracks and surface morphology. The results obtained showed a significant decrease in the number and dimensions of microcracks generated on the inner surface of drilled holes with the RUBD process in comparison to CSBD. It was also observed that a higher rotational speed and a lower feed rate resulted in lower damage, i.e. fewer microcracks. Biomechanical axial pullout strength of a cortical bone screw inserted into a hole drilled with RUBD was found to be much higher (55-385%) than that for CSBD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Evaluation of the Influence of Cervical Screws Tapping and Design

OBJECTIVE To assess if the screw design (self-drilling/self-tapping) and the pilot hole tapping could affect the insertion torque and screw pullout strength of the screw used in anterior fixation of the cervical spine. METHODS Forty self-tapping screws and 20 self-drilling screws were inserted into 10 models of artificial bone and 10 cervical vertebrae of sheep. The studied parameters were th...

متن کامل

A miniature surgical drill using ultrasonic/sonic frequency vibration

A study is presented of a miniature ultrasonic surgical drill designed for bone biopsy, based on an ultrasonic/sonic drill which converts high frequency to low frequency vibrations through a freely vibrating mass between an ultrasonic transducer-horn and a drill bit. For conventional surgical drilling using a rotary drill or an ultrasonic drill, considerable power is required to penetrate into ...

متن کامل

Presented at The Design for Manufacturability and Manufacture of Ceramic Components Symposium, American Ceramic Society 96th Annual Meeting April 24-27, 1994, Indianapolis, IN and to appear in Ceramic Transaction: Ceramic Components. 1 ROTARY ULTRASONIC DRILLING AND MILLING OF CERAMICS

An experimental study of the rotary ultrasonic drilling of ceramics is first presented. The influence of different process parameters on the material removal rate for machining of magnesia stabilized zirconia is examined. Then a mechanistic approach to modeling the material removal rate during rotary ultrasonic drilling of ceramics is proposed and applied to predicting the material removal rate...

متن کامل

Variability of the pullout strength of cancellous bone screws with cement augmentation.

BACKGROUND Orthopaedic surgeons often face clinical situations where improved screw holding power in cancellous bone is needed. Injectable calcium phosphate cements are one option to enhance fixation. METHODS Paired screw pullout tests were undertaken in which human cadaver bone was augmented with calcium phosphate cement. A finite element model was used to investigate sensitivity to screw po...

متن کامل

In-situ tool wear monitoring and its effects on the performance of porcine cortical bone drilling: a comparative in-vitro investigation

Background: Drilling is one of the most widely used process in orthopaedic surgical operation and the same drill bit is used a number of times in hospitals. Using the same drill bit a several times may be the cause of osteosynthesis and osteonecrosis. Methods: In the present work, the effect of repeated orthopaedic surgical twist drill bit on the tool wear, force, torque, temperature and chip m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical engineering & physics

دوره 41  شماره 

صفحات  -

تاریخ انتشار 2017