Performance measurements of a depth-encoding PET detector module based on position-sensitive avalanche photodiode read-out.
نویسندگان
چکیده
We are developing a high-resolution, high-efficiency positron emission tomography (PET) detector module with depth of interaction (DOI) capability based on a lutetium oxyorthosilicate (LSO) scintillator array coupled at both ends to position-sensitive avalanche photodiodes (PSAPDs). In this paper we present the DOI resolution, energy resolution and timing resolution results for complete detector modules. The detector module consists of a 7 x 7 matrix of LSO scintillator crystals (1 x 1 x 20 mm3 in dimension) coupled to 8 x 8 mm2 PSAPDs at both ends. Flood histograms were acquired and used to generate crystal look-up tables. The DOI resolution was measured for individual crystals within the array by using the ratio of the signal amplitudes from the two PSAPDs on an event-by-event basis. A measure of the total scintillation light produced was obtained by summing the signal amplitudes from the two PSAPDs. This summed signal was used to measure the energy resolution. The DOI resolution was measured to be 3-4 mm FWHM irrespective of the position of the crystal within the array, or the interaction location along the length of the crystal. The total light signal and energy resolution was almost independent of the depth of interaction. The measured energy resolution averaged 14% FWHM. The coincidence timing resolution measured using a pair of identical detector modules was 4.5 ns FWHM. These results are consistent with the design goals and the performance required of a compact, high-resolution and high-efficiency PET detector module for small animal and breast imaging applications.
منابع مشابه
Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.
UNLABELLED PET and MRI are powerful imaging techniques that are largely complementary in the information they provide. We have designed and built a MR-compatible PET scanner based on avalanche photodiode technology that allows simultaneous acquisition of PET and MR images in small animals. METHODS The PET scanner insert uses magnetic field-insensitive, position-sensitive avalanche photodiode ...
متن کاملPerformance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI.
UNLABELLED PET combined with CT has proven to be a valuable multimodality imaging device revealing both functional and anatomic information. Although PET/CT has become completely integrated into routine clinical application and also has been used in small-animal imaging, CT provides only limited soft-tissue contrast and, in preclinical studies, exposes the animal to a relatively high radiation ...
متن کاملInfluence of temperature and bias voltage on the performance of a high resolution PET detector built with position sensitive avalanche photodiodes
We evaluate the performance of an 8 × 8 array of 0.9 × 0.9 × 1 mm 3 cerium doped lutetium oxyothosilicate (LSO) crystals coupled to a position sensitive avalanche photodiode (PS-APD) as a function of bias voltage and temperature. We use this detector to develop a general methodology to optimize bias voltage, temperature, and gain for PET detectors using semiconductor photodetectors. This detect...
متن کاملA novel, SiPM-array-based, monolithic scintillator detector for PET.
Silicon photomultipliers (SiPMs) are of great interest to positron emission tomography (PET), as they enable new detector geometries, for e.g., depth-of-interaction (DOI) determination, are MR compatible, and offer faster response and higher gain than other solid-state photosensors such as avalanche photodiodes. Here we present a novel detector design with DOI correction, in which a position-se...
متن کاملA Prototype High-Resolution Small-Animal PET Scanner Dedicated to Mouse Brain Imaging.
UNLABELLED We developed a prototype small-animal PET scanner based on depth-encoding detectors using dual-ended readout of small scintillator elements to produce high and uniform spatial resolution suitable for imaging the mouse brain. METHODS The scanner consists of 16 tapered dual-ended-readout detectors arranged in a 61-mm-diameter ring. The axial field of view (FOV) is 7 mm, and the trans...