Biomechanics and shape of the above-knee socket considered in light of the ischial containment concept.
نویسنده
چکیده
In recent years considerable interest has been generated in the United States and abroad about new style above-knee prosthetic sockets, variously referred to as Narrow M-L, NASNA, CAT-CAM and SCAT-CAM. More than a little confusion has attended the process. Moreover, the impression has been created that they are not governed by the basic biomechanical rules identified by Radcliffe as affecting the quadrilateral socket. Attention has come to be focused on the role of ischial containment and the term Ischial Containment (IC) socket is enjoying widespread use. This paper reviews many of the critical features of such sockets with the goal of first demonstrating that many of these features are dictated by the requirements of ischial containment, and second that the principles set forth by Radcliffe are fully applicable. The paper concludes with a brief discussion of the alignment principles associated with Long's Line.
منابع مشابه
Biomechanics of the through-knee prosthesis.
The biomechanics of the through-knee prosthesis is considered in detail and comparisons made with the above-knee case. Socket shape and suspension are discussed and comment offered on knee function in both stance and swing phases.
متن کاملNorthwestern University Flexible Subischial Vacuum Socket for persons with transfemoral amputation: Part 2 Description and Preliminary evaluation
BACKGROUND Current transfemoral prosthetic sockets are problematic as they restrict function, lack comfort, and cause residual limb problems. Development of a subischial socket with lower proximal trim lines is an appealing way to address this problem and may contribute to improving quality of life of persons with transfemoral amputation. OBJECTIVES The purpose of this study was to illustrate...
متن کاملStump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study.
A system for measuring the stump-socket interface pressure was designed and built using a strain gauged type load cell. The system was utilized to study the pressure distribution in the quadrilateral and ischial containment type sockets. Two volunteer trans-femoral amputees fitted with both types of socket participated in the experiments. Pressures were measured while the subjects were standing...
متن کاملTransfemoral sockets with vacuum-assisted suspension comparison of hip kinematics, socket position, contact pressure, and preference: ischial containment versus brimless.
The objective of this study was to investigate the effect of brimless compared with ischial ramus containment (IRC) prosthetic sockets when using vacuum-assisted suspension (VAS) on persons with a unilateral transfemoral amputation (TFA). A randomized crossover design with a 2 d accommodation was used. People with unilateral TFA (n = 9 analyzed) were enrolled. Interventions were IRC VAS and bri...
متن کاملCoronal plane socket stability during gait in persons with transfemoral amputation: Pilot study.
Little research describes which transfemoral socket design features are important for coronal plane stability, socket comfort, and gait. Our study objectives were to (1) relate socket comfort during gait to a rank order of changes in ischial containment (IC) and tissue loading and (2) compare socket comfort during gait when tissue loading and IC were systematically manipulated. Six randomly ass...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Prosthetics and orthotics international
دوره 14 1 شماره
صفحات -
تاریخ انتشار 1990