Development of a sensitive and rapid method for quantitation of (S)-(−)- and (R)-(+)-metoprolol in human plasma by chiral LC–ESI–MS/MS
نویسندگان
چکیده
A selective, sensitive and high throughput liquid chromatography-tandem mass spectrometry (LC-ESI-MS/MS) method has been developed for separation and quantification of metoprolol enantiomers on a chiral Lux Amylose-2 (250 mm×4.6 mm, 5 μm) column. Solid phase extraction of (S)-(-)- and (R)-(+)-metoprolol and rac-metoprolol-d6 as an internal standard (IS) was achieved on Lichrosep DVB HL cartridges employing 200 μL human plasma. Both the analytes were chromatographically separated with a resolution factor of 2.24 using 15 mM ammonium acetate in water, pH 5.0 and 0.1% (v/v) diethyl amine in acetonitrile (50:50, v/v) as the mobile phase within 7.0 min. The precursor→product ion transitions for the enantiomers and IS were monitored in the multiple reaction monitoring and positive ionization mode. The method was validated over the concentration range of 0.500-500 ng/mL for both the enantiomers. Matrix effect was assessed by post-column analyte infusion experiment and the mean extraction recovery was greater than 94.0% for both the enantiomers at all quality control levels. The stability of analytes was evaluated in plasma and whole blood under different storage conditions. The method was successfully applied to a clinical study in 14 healthy volunteers after oral administration of 200 mg metoprolol tablet under fasting conditions. The assay reproducibility is shown by reanalysis of 68 incurred samples. The suitability of the developed method was assessed in comparison with different chromatographic methods developed for stereoselective analysis of metoprolol in biological matrices.
منابع مشابه
Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry
The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...
متن کاملMethod validation of clonidine hydrochloride in human plasma by LC-MS technique
A simple and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been evaluated for the assignment of clonidine hydrochloride in human plasma. The mobile phase composed of acetonitrile–water 60:40 (v/v), and 0.2% formic acid 20 µL of sample was chromatographically analyzed using a repacked ZORBAX-XDB-ODS C18 column (2.1 mm×30 m...
متن کاملA quick and Sensitive Liquid Chromatography–tandem Mass Spectrometry (LC-MS) Method for the Determination of Enalapril and Enalaprilat in Human Plasma: Application to a Bioequivalence Study
A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method for the estimation of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode was operated under the multiple-reaction monitoring mode. Sample pretreatment involved in a one-step protein precipitat...
متن کاملLiquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma
A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...
متن کاملMethod validation of methotrexate in human plasma by LC-MS technique in patients with brain tumor.
Background and aims: A selective and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been established for determination of methotrexate in human plasma. Methods: Methotrexate was extracted from plasma with acetonitrile. The mobile phase consisted of acetonitrile-water-formic acid 74: 25: 1(v/v). Twenty...
متن کامل